Osteoporosis and pathological increased occurrence of fractures are an important public health problem. They may affect patientsâEUR(TM) quality of life and even increase mortality of osteoporotic patients, and consequently represent a heavy economic burden for national healthcare systems. The adoption of simple and inexpensive methods for mass screening of population at risk may be the key for an effective prevention. The current clinical standards of diagnosing osteoporosis and assessing the risk of an osteoporotic bone fracture include dual-energy X-ray absorptiometry (DXA) and quantitative computed tomography (QCT) for the measurement of bone mineral density (BMD). Micro-computed tomography (micro-CT) is a tomographic imaging technique with very high resolution allowing direct quantification of cancellous bone microarchitecture. The Authors performed micro-CT analysis of the femoral heads harvested from 8 patients who have undergone surgery for hip replacement for primary and secondary degenerative disease to identify possible new morphometric parameters based on the analysis of the distribution of intra-subject microarchitectural parameters through the creation of parametric images. Our results show that the micro-architectural metrics commonly used may not be sufficient for the realistic assessment of bone microarchitecture of the femoral head in patients with hip osteoarthritis. The innovative micro-CT approach considers the entire femoral head in its physiological shape with all its components like cartilage, cortical layer and trabecular region. The future use of these methods for a more detailed study of the reaction of trabecular bone for the internal fixation or prostheses would be desirable.

Three-dimensional parametric mapping in quantitative micro-CT imaging of post-surgery femoral head-neck samples: Preliminary results

Panetta Daniele;
2015

Abstract

Osteoporosis and pathological increased occurrence of fractures are an important public health problem. They may affect patientsâEUR(TM) quality of life and even increase mortality of osteoporotic patients, and consequently represent a heavy economic burden for national healthcare systems. The adoption of simple and inexpensive methods for mass screening of population at risk may be the key for an effective prevention. The current clinical standards of diagnosing osteoporosis and assessing the risk of an osteoporotic bone fracture include dual-energy X-ray absorptiometry (DXA) and quantitative computed tomography (QCT) for the measurement of bone mineral density (BMD). Micro-computed tomography (micro-CT) is a tomographic imaging technique with very high resolution allowing direct quantification of cancellous bone microarchitecture. The Authors performed micro-CT analysis of the femoral heads harvested from 8 patients who have undergone surgery for hip replacement for primary and secondary degenerative disease to identify possible new morphometric parameters based on the analysis of the distribution of intra-subject microarchitectural parameters through the creation of parametric images. Our results show that the micro-architectural metrics commonly used may not be sufficient for the realistic assessment of bone microarchitecture of the femoral head in patients with hip osteoarthritis. The innovative micro-CT approach considers the entire femoral head in its physiological shape with all its components like cartilage, cortical layer and trabecular region. The future use of these methods for a more detailed study of the reaction of trabecular bone for the internal fixation or prostheses would be desirable.
2015
Istituto di Fisiologia Clinica - IFC
DEXA
Osteoporosis
Quantitative micro-CT
File in questo prodotto:
File Dimensione Formato  
prod_350618-doc_111814.pdf

solo utenti autorizzati

Descrizione: Giannotti_etal_microCT_Coxartrosis_2015
Tipologia: Versione Editoriale (PDF)
Dimensione 756.07 kB
Formato Adobe PDF
756.07 kB Adobe PDF   Visualizza/Apri   Richiedi una copia