The main drawbacks in the use of acetylcholinesterase-based biosensors are their susceptibility to inhibition by too many chemicals, their limited time-stability, and the constant need for a supply of substrates for the measurements. In order to offset these deficiencies, we have addressed our studies towards the thermophilic esterase 2 from A. acidocaldarious, which shows a high specificity and affinity towards organophosphates and a high resistance under raw operative conditions. In particular, we have investigated the possibility of measuring the binding of organophosphates to the protein by using a fluorescent probe covalently linked near the active site. We have produced a mutant where the serine 35, a residue located at the entrance of the alcohol binding site, has been replaced by a cysteine residue. The addition of 1,5-IAEDANS as a fluorescent probe to the thiol group of the mutant-protein did not affect the capability of the enzyme to bind the paraoxon and its stability or instability over time. We have set up a continuous flow system based on a re-circulating solution of the probe-enzyme complex through a fluorimetric flow cell inside a spectrofluorimeter. The addition of paraoxon aliquots has been detected in real-time by measuring the fluorescence quenching of the probe-enzyme complex. The fluorescence signals, as well as the enzyme activity, were not affected by dilution and organic solvent addition. These results support the development of biosensing devices for the continuous monitoring of organophosphate compounds.

Direct detection of organophosphate compounds in water by a fluorescence-based biosensing device

Cimmino A;Febbraio F
2017

Abstract

The main drawbacks in the use of acetylcholinesterase-based biosensors are their susceptibility to inhibition by too many chemicals, their limited time-stability, and the constant need for a supply of substrates for the measurements. In order to offset these deficiencies, we have addressed our studies towards the thermophilic esterase 2 from A. acidocaldarious, which shows a high specificity and affinity towards organophosphates and a high resistance under raw operative conditions. In particular, we have investigated the possibility of measuring the binding of organophosphates to the protein by using a fluorescent probe covalently linked near the active site. We have produced a mutant where the serine 35, a residue located at the entrance of the alcohol binding site, has been replaced by a cysteine residue. The addition of 1,5-IAEDANS as a fluorescent probe to the thiol group of the mutant-protein did not affect the capability of the enzyme to bind the paraoxon and its stability or instability over time. We have set up a continuous flow system based on a re-circulating solution of the probe-enzyme complex through a fluorimetric flow cell inside a spectrofluorimeter. The addition of paraoxon aliquots has been detected in real-time by measuring the fluorescence quenching of the probe-enzyme complex. The fluorescence signals, as well as the enzyme activity, were not affected by dilution and organic solvent addition. These results support the development of biosensing devices for the continuous monitoring of organophosphate compounds.
2017
Istituto di Biochimica delle Proteine - IBP - Sede Napoli
Istituto di genetica e biofisica "Adriano Buzzati Traverso"- IGB - Sede Napoli
Biosensing device
Flow cell
Fluorescent probe
Organophosphates
Thermophilic esterase
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/337715
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 22
  • ???jsp.display-item.citation.isi??? ND
social impact