In the present work we are studying the influence of pulse duration (nanosecond (ns) and femtosecond (fs)) at k=248 nm on the laser-induced plasma parameters and the quantitative analysis results for elements such as Sn, Zn and Pb, in different types of bronze alloys adopting LIBS in ambient atmosphere. Binary (Sn-Cu), ternary (Sn-Zn-Cu or Sn-Pb-Cu) and quaternary (Sn-Zn-Pb-Cu) reference alloys characterized by a chemical composition and metallurgical features similar to those used in Roman times, were employed in the study. Calibration curves, featuring linear regression coefficients over 98%, were obtained for tin, lead and zinc, the minor elements in the bronze alloys (using the internal standardization method) as well as for copper, the major element. The effects of laser pulse duration and energy on laser-induced plasma parameters, namely the excitation temperature and the electron density have been studied in our effort to optimize the analysis. Finally, LIBS analysis was carried on three real metal objects and the spectra obtained have been used to estimate the type and elemental composition of the alloys based on the calibration curves produced with the reference alloys. The results obtained are very useful in the future use of portable LIBS systems for in situ qualitative and quantitative elemental analysis of bronze artifacts in museums and archaeological sites.

Nanosecond and femtosecond Laser Induced Breakdown Spectroscopic analysis of bronze alloys

GM Ingo;
2008

Abstract

In the present work we are studying the influence of pulse duration (nanosecond (ns) and femtosecond (fs)) at k=248 nm on the laser-induced plasma parameters and the quantitative analysis results for elements such as Sn, Zn and Pb, in different types of bronze alloys adopting LIBS in ambient atmosphere. Binary (Sn-Cu), ternary (Sn-Zn-Cu or Sn-Pb-Cu) and quaternary (Sn-Zn-Pb-Cu) reference alloys characterized by a chemical composition and metallurgical features similar to those used in Roman times, were employed in the study. Calibration curves, featuring linear regression coefficients over 98%, were obtained for tin, lead and zinc, the minor elements in the bronze alloys (using the internal standardization method) as well as for copper, the major element. The effects of laser pulse duration and energy on laser-induced plasma parameters, namely the excitation temperature and the electron density have been studied in our effort to optimize the analysis. Finally, LIBS analysis was carried on three real metal objects and the spectra obtained have been used to estimate the type and elemental composition of the alloys based on the calibration curves produced with the reference alloys. The results obtained are very useful in the future use of portable LIBS systems for in situ qualitative and quantitative elemental analysis of bronze artifacts in museums and archaeological sites.
2008
Istituto per lo Studio dei Materiali Nanostrutturati - ISMN
Inglese
63
4
504
511
8
Sì, ma tipo non specificato
Femtosecond and nanosecond LIBS; Bronze alloys; Simulated artifacts; Plasma parameters
In the present work we are studying the influence of pulse duration (nanosecond (ns) and femtosecond (fs)) at k=248 nm on the laser-induced plasma parameters and the quantitative analysis results for elements such as Sn, Zn and Pb, in different types of bronze alloys adopting LIBS in ambient atmosphere. Binary (Sn-Cu), ternary (Sn-Zn-Cu or Sn-Pb-Cu) and quaternary (Sn-Zn-Pb-Cu) reference alloys characterized by a chemical composition and metallurgical features similar to those used in Roman times, were employed in the study. Calibration curves, featuring linear regression coefficients over 98%, were obtained for tin, lead and zinc, the minor elements in the bronze alloys (using the internal standardization method) as well as for copper, the major element. The effects of laser pulse duration and energy on laser-induced plasma parameters, namely the excitation temperature and the electron density have been studied in our effort to optimize the analysis. Finally, LIBS analysis was carried on three real metal objects and the spectra obtained have been used to estimate the type and elemental composition of the alloys based on the calibration curves produced with the reference alloys. The results obtained are very useful in the future use of portable LIBS systems for in situ qualitative and quantitative elemental analysis of bronze artifacts in museums and archaeological sites.
1
info:eu-repo/semantics/article
262
A. Elhassan; A. Giakoumaki; D. Anglos; G.M. Ingo; L. Robbiola; M.A. Harith
01 Contributo su Rivista::01.01 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/33849
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 97
social impact