This study describes an actuated bioreactor which mimics the pulsatile contractile motion of the intestinal barrier using electro-responsive elastomers as smart materials that undergo deformation upon electrical stimulation. The device consists of an annular dielectric elastomer actuator working as a radial artificial muscle able to rhythmically contract and relax a central cell culture well. The bioreactor maintained up to 4 h of actuation at a frequency of 0.15 Hz and a strain of 8%-10%, to those of the cyclic contraction and relaxation of the small intestine. In vitro tests demonstrated that the device was biocompatible and cell-adhesive for Caco-2 cells, which formed a confluent monolayer following 21 days of culture in the central well. In addition, cellular adhesion and cohesion were maintained after 4 h of continuous cyclic strain. These preliminary results encourage further investigations on the use of dielectric elastomer actuation as a versatile technology that might overcome the limitations of commercially available pneumatic driving systems to obtain bioreactors that can cyclically deform cell cultures in a biomimetic fashion.

A bioreactor with an electro-responsive elastomeric membrane for mimicking intestinal peristalsis

Domenici Claudio;
2017

Abstract

This study describes an actuated bioreactor which mimics the pulsatile contractile motion of the intestinal barrier using electro-responsive elastomers as smart materials that undergo deformation upon electrical stimulation. The device consists of an annular dielectric elastomer actuator working as a radial artificial muscle able to rhythmically contract and relax a central cell culture well. The bioreactor maintained up to 4 h of actuation at a frequency of 0.15 Hz and a strain of 8%-10%, to those of the cyclic contraction and relaxation of the small intestine. In vitro tests demonstrated that the device was biocompatible and cell-adhesive for Caco-2 cells, which formed a confluent monolayer following 21 days of culture in the central well. In addition, cellular adhesion and cohesion were maintained after 4 h of continuous cyclic strain. These preliminary results encourage further investigations on the use of dielectric elastomer actuation as a versatile technology that might overcome the limitations of commercially available pneumatic driving systems to obtain bioreactors that can cyclically deform cell cultures in a biomimetic fashion.
2017
Istituto di Fisiologia Clinica - IFC
dielectric elastomer actuator
bioreactor
in vitro model
intestinal contraction
artificial muscle
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/338520
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact