The paper discusses experimental and numerical seismic analyses of typical connections and wall systems used in cross-laminated (X-Lam) timber buildings. An extended experimental programme on typical X-Lam connections was performed at IVALSA Trees and Timber Institute. In addition, cyclic tests were also carried out on full-scale single and coupled X-Lam wall panels with different configurations and mechanical connectors subjected to lateral force. An advanced non-linear hysteretic spring to describe accurately the cyclic behaviour of connections was implemented in ABAQUS finite element software package as an external subroutine. The FE model with the springs calibrated on single connection tests was then used to reproduce numerically the behaviour of X-Lam wall panels, and the results were compared with the outcomes of experimental full-scale tests carried out at IVALSA. The developed model is suitable for evaluating dissipated energy and seismic vulnerability of X-Lam structures.

Experimental-numerical analyses of the seismic behaviour of cross-laminated wall systems

Ceccotti A
2012

Abstract

The paper discusses experimental and numerical seismic analyses of typical connections and wall systems used in cross-laminated (X-Lam) timber buildings. An extended experimental programme on typical X-Lam connections was performed at IVALSA Trees and Timber Institute. In addition, cyclic tests were also carried out on full-scale single and coupled X-Lam wall panels with different configurations and mechanical connectors subjected to lateral force. An advanced non-linear hysteretic spring to describe accurately the cyclic behaviour of connections was implemented in ABAQUS finite element software package as an external subroutine. The FE model with the springs calibrated on single connection tests was then used to reproduce numerically the behaviour of X-Lam wall panels, and the results were compared with the outcomes of experimental full-scale tests carried out at IVALSA. The developed model is suitable for evaluating dissipated energy and seismic vulnerability of X-Lam structures.
2012
Istituto per la Valorizzazione del Legno e delle Specie Arboree - IVALSA - Sede Sesto Fiorentino
Experimental tests
Components approach
Connections
X-Lam wall systems
Numerical analysis
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/340314
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact