Electrochemical impedance spectroscopy (EIS) and gravimetric measurements on two water-based coatings, containing either SrCrO4 or a mixture of Cr(VI)-free pigments and deposited on 2024 aluminium alloy, were performed to follow the water uptake in a 0.5 M NaCl solution as a function of exposure time. To account for the observed non-ideal capacitive behaviour, the coating capacitance and dielectric constant values were extracted from the EIS data in two ways: (i) by using a complex-capacitance representation and (ii) by fitting to the EIS data a model that assumed an exponential distribution of coating resistivity. The agreement of values obtained by these independent methods served to validate the model used to account for the observed pseudo constantphase- element (CPE) behaviour of the coatings. The water uptake calculated from dielectric constant values, employing a linear combination formula, was in good agreement with that directly measured by gravimetry, using supported-films.[object Object]

Determination of water uptake in organic coatings deposited on 2024 aluminium alloy: Comparison between impedance measurements and gravimetry

Musiani M;
2017

Abstract

Electrochemical impedance spectroscopy (EIS) and gravimetric measurements on two water-based coatings, containing either SrCrO4 or a mixture of Cr(VI)-free pigments and deposited on 2024 aluminium alloy, were performed to follow the water uptake in a 0.5 M NaCl solution as a function of exposure time. To account for the observed non-ideal capacitive behaviour, the coating capacitance and dielectric constant values were extracted from the EIS data in two ways: (i) by using a complex-capacitance representation and (ii) by fitting to the EIS data a model that assumed an exponential distribution of coating resistivity. The agreement of values obtained by these independent methods served to validate the model used to account for the observed pseudo constantphase- element (CPE) behaviour of the coatings. The water uptake calculated from dielectric constant values, employing a linear combination formula, was in good agreement with that directly measured by gravimetry, using supported-films.[object Object]
2017
Istituto di Chimica della Materia Condensata e di Tecnologie per l'Energia - ICMATE
Inglese
112
93
100
http://www.sciencedirect.com/science/article/pii/S0300944017302990?via%3Dihub
Sì, ma tipo non specificato
Water-based protective coatings
Electrochemical impedance
Complex-capacitance
Resistivity distribution
Water uptake
Highlights o Complex-capacitance representation was used to follow coating capacitance variation during immersion in the electrolyte. o Impedance data were analysed assuming an exponential distribution of coating resistivity. o Chromates leaching was quantified to accurately analyse the impedance data. o Water uptake was determined by gravimetric measurements and compared with calculated values from dielectric constant values. o Measured water uptake was in agreement with that calculated by employing a linear combination formula.
7
info:eu-repo/semantics/article
262
Nguyen, As; Causse, N; Musiani, M; Orazem, Me; Pebere, N; Tribollet, B; Vivier, V
01 Contributo su Rivista::01.01 Articolo in rivista
open
File in questo prodotto:
File Dimensione Formato  
prod_378714-doc_128549.pdf

accesso aperto

Descrizione: Determination of water uptake in organic coatings deposited on 2024 aluminium alloy...
Tipologia: Versione Editoriale (PDF)
Dimensione 964.01 kB
Formato Adobe PDF
964.01 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/340442
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 74
  • ???jsp.display-item.citation.isi??? 72
social impact