Here we report on a high-sensitivity interferometric technique, namely Interferogram Averaged over Wavelength - IAW-reflectance spectroscopy, enabling sub-nanomolar detection (both nonspecific and specific) of proteins to be accomplished in direct (without any amplification) label-free mode using porous silicon (PSi) interferometers. The IAW reflectance spectroscopy is based on both calculation and elaboration of spectral interferograms. Interferograms are obtained by subtracting (intensity, wavelength by wavelength) reflectance spectra acquired on PSi interferometers in buffer solution after protein injection (at different concentrations) from a reference reflectance spectrum acquired in buffer solution before protein injection. The output signal, namely IAW value, is eventually obtained as the average value, calculated over a given wavelength interval, of each interferogram. Using the IAW technique nonspecific adsorption of Bovine Serum Albumin (BSA) down to 0.15 nM (DL=20 pM) and specific detection of Tumor Necrosis Factor (TNF?) down to 3 nM (DL=0.2 nM) was reliably achieved in direct label-free mode using PSi interferometers. Both the results represent a 10000-fold reduction in DL with respect to the current literature on the use of PSi for direct label-free measurements.

Interferogram average over wavelength spectroscopy: An ultrasensitive technique for biosensing with porous silicon interferometers

Strambini L;Tedeschi L;
2017

Abstract

Here we report on a high-sensitivity interferometric technique, namely Interferogram Averaged over Wavelength - IAW-reflectance spectroscopy, enabling sub-nanomolar detection (both nonspecific and specific) of proteins to be accomplished in direct (without any amplification) label-free mode using porous silicon (PSi) interferometers. The IAW reflectance spectroscopy is based on both calculation and elaboration of spectral interferograms. Interferograms are obtained by subtracting (intensity, wavelength by wavelength) reflectance spectra acquired on PSi interferometers in buffer solution after protein injection (at different concentrations) from a reference reflectance spectrum acquired in buffer solution before protein injection. The output signal, namely IAW value, is eventually obtained as the average value, calculated over a given wavelength interval, of each interferogram. Using the IAW technique nonspecific adsorption of Bovine Serum Albumin (BSA) down to 0.15 nM (DL=20 pM) and specific detection of Tumor Necrosis Factor (TNF?) down to 3 nM (DL=0.2 nM) was reliably achieved in direct label-free mode using PSi interferometers. Both the results represent a 10000-fold reduction in DL with respect to the current literature on the use of PSi for direct label-free measurements.
2017
Istituto di Elettronica e di Ingegneria dell'Informazione e delle Telecomunicazioni - IEIIT
Inglese
231st ECS Meeting
77
1815
1823
http://www.scopus.com/record/display.url?eid=2-s2.0-85030543721&origin=inward
Electrochemical Society Inc.
Pennington
STATI UNITI D'AMERICA
Sì, ma tipo non specificato
28/05/2017, 01/06/2017
New Orleans; United States
Porous silicon
Interferometric techniques
Nanomolar detection
Reflectance spectroscopy
biosensing
4
none
Mariani, S; Strambini, L; Tedeschi, L; Barillaro, G
273
info:eu-repo/semantics/conferenceObject
04 Contributo in convegno::04.01 Contributo in Atti di convegno
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/341868
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? ND
social impact