Here we report on a high-sensitivity label-free interferometric technique (i.e. Interferogram Average over Wavelength, IAW, reflectance spectroscopy) for, though not limited to,porous silicon (PSi) nanosructured interferometers. The IAW reflectance spectroscopy was set up studying nonpecific adsorption of Bovine Serum Albumin (BSA) onto oxidized PSi interferometers and then validated through the development of an aptasensor using PSi interferometers for the specific detection of Tumor Necrosis Factor ? (TNF?, a sepsis biomarker). In both the cases we demonstrated that sub-nanomolar detection limits (DLs) can be achieved, which are 4 orders of magnitude lower than DLs achieved using Fast Fourier Transform (FFT) reflectance spectroscopy (usually in the micromolar range), in direct label-free operation. These results open exciting perspectives for point of care (POC) analysis based on PSi interferometers, for which increasingly lower detection limits are required.

Porous Silicon Interferometers for High-Sensitivity Label-Free Detection of Biomolecules

Strambini L;Tedeschi L;
2017

Abstract

Here we report on a high-sensitivity label-free interferometric technique (i.e. Interferogram Average over Wavelength, IAW, reflectance spectroscopy) for, though not limited to,porous silicon (PSi) nanosructured interferometers. The IAW reflectance spectroscopy was set up studying nonpecific adsorption of Bovine Serum Albumin (BSA) onto oxidized PSi interferometers and then validated through the development of an aptasensor using PSi interferometers for the specific detection of Tumor Necrosis Factor ? (TNF?, a sepsis biomarker). In both the cases we demonstrated that sub-nanomolar detection limits (DLs) can be achieved, which are 4 orders of magnitude lower than DLs achieved using Fast Fourier Transform (FFT) reflectance spectroscopy (usually in the micromolar range), in direct label-free operation. These results open exciting perspectives for point of care (POC) analysis based on PSi interferometers, for which increasingly lower detection limits are required.
2017
Istituto di Elettronica e di Ingegneria dell'Informazione e delle Telecomunicazioni - IEIIT
Porous Silicon
Label-free Biosensor
Nanostructured Surface
Optical Interfer
Aptasensor
Aptamer
TNF?
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/342287
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact