By using the micro-beam, the map of the charge collection efficiency for both the detectors have been measured. We show that the charge collection efficiency of the diamond with large contacts is generally uniform, while the diamond with smaller contacts needs further developments in this respect.
The proton micro-beam of the CNA accelerator in Seville has been used to test two detectors based on single crystal diamond grown by chemical vapor deposition. The first diamond has a more traditional design, with dimensions 4.5 x 4.5 x 0.5 mm(3), and features a large contact of the same size as the crystal. The second, with dimensions 2.0 x 2.0 x 0.3 mm3, features a small contact of 0.5 x 0.5 mm(2).
Charge collection uniformity and irradiation effects of synthetic diamond detectors studied with a proton micro-beam
Rebai M;Girolami M;Trucchi D M;Bellucci A;Tardocchi M;
2017
Abstract
The proton micro-beam of the CNA accelerator in Seville has been used to test two detectors based on single crystal diamond grown by chemical vapor deposition. The first diamond has a more traditional design, with dimensions 4.5 x 4.5 x 0.5 mm(3), and features a large contact of the same size as the crystal. The second, with dimensions 2.0 x 2.0 x 0.3 mm3, features a small contact of 0.5 x 0.5 mm(2).| File | Dimensione | Formato | |
|---|---|---|---|
|
prod_375222-doc_186372.pdf
accesso aperto
Descrizione: Preprint
Tipologia:
Versione Editoriale (PDF)
Dimensione
946.48 kB
Formato
Adobe PDF
|
946.48 kB | Adobe PDF | Visualizza/Apri |
|
prod_375222-doc_186378.pdf
solo utenti autorizzati
Descrizione: Articolo pubblicato
Tipologia:
Versione Editoriale (PDF)
Dimensione
5.86 MB
Formato
Adobe PDF
|
5.86 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.