In this paper, we deal with the problem of tracking a desired plasma glucose concentration by means of intravenous insulin administration, for Type 2 diabetic patients. A nonlinear time-delay model is used to describe the glucose-insulin regulatory system, according to which a model-based approach is exploited to design a semiglobal sampled-data dynamic output feedback controller. It is shown that emulation, by Euler approximation, of a proposed continuous-time control law yields stabilization in the sample-and-hold sense of the glucose-insulin system. The glucose regulator makes use of only sampled glucose measurements. Theoretical results are preclinically validated through a virtual environment broadly accepted as a substitute to animal trials for the preclinical testing of control strategies in plasma glucose regulation. Numerical results are encouraging and pave the way to further clinical verifications.

Semiglobal Sampled-Data Dynamic Output Feedback Controller for the Glucose-Insulin System

Pasquale Palumbo;Simona Panunzi;Andrea De Gaetano
2018

Abstract

In this paper, we deal with the problem of tracking a desired plasma glucose concentration by means of intravenous insulin administration, for Type 2 diabetic patients. A nonlinear time-delay model is used to describe the glucose-insulin regulatory system, according to which a model-based approach is exploited to design a semiglobal sampled-data dynamic output feedback controller. It is shown that emulation, by Euler approximation, of a proposed continuous-time control law yields stabilization in the sample-and-hold sense of the glucose-insulin system. The glucose regulator makes use of only sampled glucose measurements. Theoretical results are preclinically validated through a virtual environment broadly accepted as a substitute to animal trials for the preclinical testing of control strategies in plasma glucose regulation. Numerical results are encouraging and pave the way to further clinical verifications.
2018
Istituto di Analisi dei Sistemi ed Informatica ''Antonio Ruberti'' - IASI
Glucose-insulin model
nonlinear time-delay systems
sampled-data output feedback controllers
stabilization in the sample-and-hold sense
in silico validation
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/344425
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact