In this paper we studied the correlation of the acquired spectra shape with the post acceleration voltage and with the detector polarization condition. An increase in the spectra intensity was observed and studied with increasing both detector reverse bias and post acceleration voltage. Obtained results demonstrate that interdigit 4H-SiC diodes with millimetric size, show a quite good efficiency for ion detection with energy higher than 5 keV and are very promising devices allowing, thanks to their millimetric size, to carry out detectors array systems for the measurement of the spatial distribution of low energy ions generated by pulsed laser-plasmas. (C) 2016 Elsevier Ltd. All rights reserved.

The ion streams emitted from laser generated plasmas and post-accelerated through a high voltage acceleration path, were monitored by solid state 4H-SiC interdigit detectors in time-of-flight configuration. The plasmas are produced by irradiation of an aluminum target through a ns pulsed laser with 10(10) w/cm(2) intensity and 200 mJ pulse energy. Laser-generated plasma exhibits a mean energy of the order of 100 eV per amu. In order to enhance the ion kinetic energy a post acceleration in the range 1 kV -30 kV was employed.

SiC interdigit detectors for post-accelerated ions generated by laser plasma

Sciuto A;
2016

Abstract

The ion streams emitted from laser generated plasmas and post-accelerated through a high voltage acceleration path, were monitored by solid state 4H-SiC interdigit detectors in time-of-flight configuration. The plasmas are produced by irradiation of an aluminum target through a ns pulsed laser with 10(10) w/cm(2) intensity and 200 mJ pulse energy. Laser-generated plasma exhibits a mean energy of the order of 100 eV per amu. In order to enhance the ion kinetic energy a post acceleration in the range 1 kV -30 kV was employed.
2016
In this paper we studied the correlation of the acquired spectra shape with the post acceleration voltage and with the detector polarization condition. An increase in the spectra intensity was observed and studied with increasing both detector reverse bias and post acceleration voltage. Obtained results demonstrate that interdigit 4H-SiC diodes with millimetric size, show a quite good efficiency for ion detection with energy higher than 5 keV and are very promising devices allowing, thanks to their millimetric size, to carry out detectors array systems for the measurement of the spatial distribution of low energy ions generated by pulsed laser-plasmas. (C) 2016 Elsevier Ltd. All rights reserved.
Laser plasma
Ion detectors
Silicon carbide
Schottky detector
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/346759
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact