The gas supply for the neutralizer of the Heating Neutral Beam is designed to guarantee the establishment of the gas cloud needed to neutralize the negative ion beam, generated in the beam source, before it can be injected into the tokamak for plasma heating. To guarantee the proper function for optimal beam properties, an experimental validation of the analytical predictions of the gas flow behavior under the conditions of the test facility MITICA (Megavolt ITER Injector and Concept Advancement) was needed. Herewith the throughput properties of the designed gas injection nozzles had to be investigated as well as the behavior of the system in case of a sudden shutdown of the supply. These experiments have been performed at the modified TransFlow facility at KIT. Additionally, the experimental results have been compared with simulations and some effort was spent in order to find proper material and mounting options for the nozzles.

Experimental characterization of the gas injection nozzle for the ITER Neutral Beam Test Facility neutralizer

Dalla Palma Mauro;Zaccaria Pierluigi;
2017

Abstract

The gas supply for the neutralizer of the Heating Neutral Beam is designed to guarantee the establishment of the gas cloud needed to neutralize the negative ion beam, generated in the beam source, before it can be injected into the tokamak for plasma heating. To guarantee the proper function for optimal beam properties, an experimental validation of the analytical predictions of the gas flow behavior under the conditions of the test facility MITICA (Megavolt ITER Injector and Concept Advancement) was needed. Herewith the throughput properties of the designed gas injection nozzles had to be investigated as well as the behavior of the system in case of a sudden shutdown of the supply. These experiments have been performed at the modified TransFlow facility at KIT. Additionally, the experimental results have been compared with simulations and some effort was spent in order to find proper material and mounting options for the nozzles.
2017
Istituto gas ionizzati - IGI - Sede Padova
Inglese
123
276
280
5
https://www.sciencedirect.com/science/article/pii/S0920379617306026
Sì, ma tipo non specificato
HNB
MITICA
Neutralizer
Gas injection
TransFlow
Electronic ISSN: 1873-7196 / The work leading to this publication has been funded partially by Fusion for Energy under the Contract F4E-RFX-PMS A-WP-2016 and embedded in the Agreement on the Neutral Beam Test Facility between RFX and KIT. / https://biblioproxy.cnr.it:2562/S0920379617306026/1-s2.0-S0920379617306026-main.pdf?_tid=7aee5216-17f0-11e8-8c4a-00000aacb35e&acdnat=1519318414_9ac614269b3f3032630e9fba69630227
2
info:eu-repo/semantics/article
262
Hanke, Stefan; Hauer, Volker; Day, Christian; Dalla Palma, Mauro; Sartori, Emanuele; Dal Bello, Samuele; Zaccaria, Pierluigi; Zhang, Mingxing
01 Contributo su Rivista::01.01 Articolo in rivista
none
   EU Fusion for ITER Applications
   EUFORIA
   FP7
   211804
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/348413
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 4
social impact