ITER Neutral Beam Injectors (NBIs) need to be shielded from the relatively strong stray magnetic field generated by the Poloidal Field Coils of the Tokamak. For this reason both the Heating Neutral Beams (HNB) and the Diagnostic Neutral Beam (DNB) will be provided with a Passive Magnetic Shield and with a system of Active Correction and Compensation Coils (ACCC). The ACCC will operate in feedback control and thus require the measurement of magnetic field inside the NBI vessel, i.e. in an environment subjected to the neutron flux coming from the Tokamak. To this purpose, magnetic sensors which are robust, radiation hard, drift-immune and remote-handling compatible are required. Flux-gate magnetic sensors are a good candidate for this task, but commercial sensors of this kind have typically a limited measured range (below 0.1 mT). The feasibility of a flux-gate sensor for the ITER NBI has been studied by developing a numerical model which includes magnetic core hysteresis, and which demonstrated that, by suitable choice of the core magnetic properties and geometry, itis possible to increase the measurement range by atleast 2 orders of magnitude. On this basis, a flux-gate sensor prototype has been realized at Consorzio RFX. Experimental tests carried out so far have demonstrated that the measurement range can be increased to ~10 mT with acceptable accuracy and frequency bandwidth.

Feasibility study of a flux-gate magnetic field sensor suitable for ITER neutral beam injectors

Brombin M;
2017

Abstract

ITER Neutral Beam Injectors (NBIs) need to be shielded from the relatively strong stray magnetic field generated by the Poloidal Field Coils of the Tokamak. For this reason both the Heating Neutral Beams (HNB) and the Diagnostic Neutral Beam (DNB) will be provided with a Passive Magnetic Shield and with a system of Active Correction and Compensation Coils (ACCC). The ACCC will operate in feedback control and thus require the measurement of magnetic field inside the NBI vessel, i.e. in an environment subjected to the neutron flux coming from the Tokamak. To this purpose, magnetic sensors which are robust, radiation hard, drift-immune and remote-handling compatible are required. Flux-gate magnetic sensors are a good candidate for this task, but commercial sensors of this kind have typically a limited measured range (below 0.1 mT). The feasibility of a flux-gate sensor for the ITER NBI has been studied by developing a numerical model which includes magnetic core hysteresis, and which demonstrated that, by suitable choice of the core magnetic properties and geometry, itis possible to increase the measurement range by atleast 2 orders of magnitude. On this basis, a flux-gate sensor prototype has been realized at Consorzio RFX. Experimental tests carried out so far have demonstrated that the measurement range can be increased to ~10 mT with acceptable accuracy and frequency bandwidth.
2017
Istituto gas ionizzati - IGI - Sede Padova
Inglese
123
412
416
5
https://www.sciencedirect.com/science/article/pii/S0920379617302909
Sì, ma tipo non specificato
Flux-gate sensor
Magnetic hysteresis
Neutral beam injector
ITER
Electronic ISSN: 1873-7196 / This work has been funded partially by Fusion for Energy under the Contract No. F4E- RFXPMS A-WP-2015 and 2016. / http://biblioproxy.cnr.it:2084/full_record.do?product=WOS&search_mode=GeneralSearch&qid=3&SID=D6nSvUMAstiuQ32O3qD&page=1&doc=1
5
info:eu-repo/semantics/article
262
Chitarin, G; Aprile, D; Brombin, M; Marconato, N; Svensson, L
01 Contributo su Rivista::01.01 Articolo in rivista
none
   EU Fusion for ITER Applications
   EUFORIA
   FP7
   211804
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/350596
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact