After installation of Mo liners in the source NIO1 (Negative Ion Optimization phase 1), hydrogen plasmas in a continuous regime operation (much longer than one hour) are routinely maintained, with more than 1 kW rf power and 0.5 Pa pressure, allowing a systematic investigation of pure H- volume effect, which requests a much lower acceleration voltage Vs 12 kV than future Cs operations at Vs 60 kV . A new extraction grid EG was installed (replacing some eroded insulators) and preliminary beam images are compared to old EG ones, discussing effects of different deflection field strength and need of intermediate values. Large improvements in beam diagnostics and the effect of installation of a cryogenic pump are also reported.

Extraction of many H-beamlets from ion source NIO1

Serianni G;Agostini M;Antoni V;Barbato P;Barbisan M;Brombin M;Cervaro V;Maniero M;Minelli P;Pasqualotto R;Recchia M;Romanato L;Rossetto F;Taccogna F;
2018

Abstract

After installation of Mo liners in the source NIO1 (Negative Ion Optimization phase 1), hydrogen plasmas in a continuous regime operation (much longer than one hour) are routinely maintained, with more than 1 kW rf power and 0.5 Pa pressure, allowing a systematic investigation of pure H- volume effect, which requests a much lower acceleration voltage Vs 12 kV than future Cs operations at Vs 60 kV . A new extraction grid EG was installed (replacing some eroded insulators) and preliminary beam images are compared to old EG ones, discussing effects of different deflection field strength and need of intermediate values. Large improvements in beam diagnostics and the effect of installation of a cryogenic pump are also reported.
2018
Istituto gas ionizzati - IGI - Sede Padova
Istituto di Nanotecnologia - NANOTEC
Inglese
17th International Conference on Ion Sources (ICIS 2017)
2011
050006-1
050006-3
3
9780735417274
https://aip.scitation.org/doi/abs/10.1063/1.5053304
AMER INST PHYSICS, CIRCULATION & FULFILLMENT DIV, 2 HUNTINGTON QUADRANGLE, STE 1 N O 1
MELVILLE, NY 11747-4501
STATI UNITI D'AMERICA
September 15-20, 2017
Geneva (Switzerland)
NIO1
Negative Ion Optimization 1
H-beamlets
hydrogen plasmas
Article Number: 050006 / http://www.scopus.com/inward/record.url?eid=2-s2.0-85054158932&partnerID=q2rCbXpz / Electronic ISSN: 1551-7616.
53
restricted
Cavenago, M; Serianni, G; Veltri, P; De Muri, M; Agostini, M; Antoni, V; Baltador, C; Barbato, P; Barbisan, M; Barzon, A; Baseggio, L; Bigi, M; Brombi...espandi
273
info:eu-repo/semantics/conferenceObject
04 Contributo in convegno::04.01 Contributo in Atti di convegno
   Implementation of activities described in the Roadmap to Fusion during Horizon 2020 through a Joint programme of the members of the EUROfusion consortium
   EUROfusion
   H2020
   633053
File in questo prodotto:
File Dimensione Formato  
prod_392947-doc_135905.pdf

solo utenti autorizzati

Descrizione: Extraction of many H_beamlets from ion source NIO1
Tipologia: Versione Editoriale (PDF)
Dimensione 1.36 MB
Formato Adobe PDF
1.36 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/350945
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact