The NIO1 experiment hosts a flexible RF H- ion source, developed by INFN-LNL and Consorzio RFX to improve the present concepts for the production and acceleration of negative ions. The source is also used to benchmark the instrumentation dedicated to the ITER neutral beam test facility. Many diagnostics are installed in NIO1 to characterize the source and the extracted negative ion beam. Among them, Beam Emission Spectroscopy (BES) has been used in NIO1 to measure the divergence and the uniformity of the beam, together with the fraction of beam ions which was neutralized inside the acceleration system. The diagnostic method is based on the analysis of the Doppler shifted H? photons emitted by the fast beam particles and collected along a line of sight. The article presents the experimental setup and the analysis algorithms of the BES diagnostic, together with a discussion of the first measurements and of their correlation with the operational parameters.

First beam characterization by means of emission spectroscopy in the NIO1 experiment

Barbisan M;Serianni G;Pasqualotto R
2018

Abstract

The NIO1 experiment hosts a flexible RF H- ion source, developed by INFN-LNL and Consorzio RFX to improve the present concepts for the production and acceleration of negative ions. The source is also used to benchmark the instrumentation dedicated to the ITER neutral beam test facility. Many diagnostics are installed in NIO1 to characterize the source and the extracted negative ion beam. Among them, Beam Emission Spectroscopy (BES) has been used in NIO1 to measure the divergence and the uniformity of the beam, together with the fraction of beam ions which was neutralized inside the acceleration system. The diagnostic method is based on the analysis of the Doppler shifted H? photons emitted by the fast beam particles and collected along a line of sight. The article presents the experimental setup and the analysis algorithms of the BES diagnostic, together with a discussion of the first measurements and of their correlation with the operational parameters.
2018
Istituto gas ionizzati - IGI - Sede Padova
9780735417274
NIO1
Negative Ion Optimization 1
Beam Emission Spectroscopy
BES
BES Diagnostic
File in questo prodotto:
File Dimensione Formato  
prod_392964-doc_135910.pdf

solo utenti autorizzati

Descrizione: First beam characterization by means of emission spectroscopy in the NIO1 experiment
Tipologia: Versione Editoriale (PDF)
Dimensione 819.66 kB
Formato Adobe PDF
819.66 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/350962
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 2
social impact