A dedicated experiment on beam-target neutron emission has been performed at the ELISE neutral beam test facility to investigate the accuracy of Local Mixing Model based calculations of neutron emission of relevance for the design of neutron diagnostics at the SPIDER neutral beam prototype. Compared to a previous experiment, we make use of fully developed infra-red and calorimetry diagnostics to include accurate data on beam profile and current in the calculations. Results show that variations of the neutron emission can be predicted with an accuracy better than 10%, which compares to 30% in our previous investigation. At the same time, convincing evidence of diffusion effects beyond the Local Mixing Model is identified in the data. Implications of these findings for neutron emission at SPIDER are discussed. (C) 2017 Elsevier B.V. All rights reserved.

Experimental investigation of beam-target neutron emission at the ELISE neutral beam test facility

Pasqualotto R;Tardocchi M;Gorini G
2017

Abstract

A dedicated experiment on beam-target neutron emission has been performed at the ELISE neutral beam test facility to investigate the accuracy of Local Mixing Model based calculations of neutron emission of relevance for the design of neutron diagnostics at the SPIDER neutral beam prototype. Compared to a previous experiment, we make use of fully developed infra-red and calorimetry diagnostics to include accurate data on beam profile and current in the calculations. Results show that variations of the neutron emission can be predicted with an accuracy better than 10%, which compares to 30% in our previous investigation. At the same time, convincing evidence of diffusion effects beyond the Local Mixing Model is identified in the data. Implications of these findings for neutron emission at SPIDER are discussed. (C) 2017 Elsevier B.V. All rights reserved.
2017
Istituto di fisica del plasma - IFP - Sede Milano
Istituto gas ionizzati - IGI - Sede Padova
Beam-target neutron emission
Neutral beam injection
Neutron detectors
File in questo prodotto:
File Dimensione Formato  
prod_384616-doc_131588.pdf

solo utenti autorizzati

Descrizione: Experimental investigation of beam_target neutron emission at the ELISE neutral beam test facility
Tipologia: Versione Editoriale (PDF)
Dimensione 672.01 kB
Formato Adobe PDF
672.01 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/351142
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact