This work discusses the results appearing in Wu et al.'s (2014) article dealing with three aliphatic-aromatic polyesters based on terephthalic acid and their spectral identification. Using an instrument equipped with a switch that allows ions with masses below 5kDa to be discarded (ion deflector), the authors report the MALDI spectrum of a commercial poly(ethylene terephthalate) with signals up to 80kDa. I plot the spectral intensities and fit them with a Gaussian curve. The result is carefully examined. Thereafter, attention is moved to the MALDI spectra obtained when the ion deflector is turned off. A computation that gives the number-average and the weight-average molar mass (Mn and Mw) was performed, but the result was Mn=1362g/mol and Mw=1416g/mol. These values are much too low and they cannot be used. In order to explain this failure, I modified a model developed for poly(pentylene adipate). This hypothesis is discarded and the correct explanation is found. I also discuss other types of instrumentation, for instance, Py-GC/MS combined with library-search and also NMR spectroscopy, with specific reference to the chemical shifts of the -CH2- protons in aliphatic-aromatic polyesters.

Some Comments on a Recent Article Dealing with Three Aliphatic-Aromatic Polyesters and Their Spectral Identification

Montaudo;
2015

Abstract

This work discusses the results appearing in Wu et al.'s (2014) article dealing with three aliphatic-aromatic polyesters based on terephthalic acid and their spectral identification. Using an instrument equipped with a switch that allows ions with masses below 5kDa to be discarded (ion deflector), the authors report the MALDI spectrum of a commercial poly(ethylene terephthalate) with signals up to 80kDa. I plot the spectral intensities and fit them with a Gaussian curve. The result is carefully examined. Thereafter, attention is moved to the MALDI spectra obtained when the ion deflector is turned off. A computation that gives the number-average and the weight-average molar mass (Mn and Mw) was performed, but the result was Mn=1362g/mol and Mw=1416g/mol. These values are much too low and they cannot be used. In order to explain this failure, I modified a model developed for poly(pentylene adipate). This hypothesis is discarded and the correct explanation is found. I also discuss other types of instrumentation, for instance, Py-GC/MS combined with library-search and also NMR spectroscopy, with specific reference to the chemical shifts of the -CH2- protons in aliphatic-aromatic polyesters.
2015
Istituto per i Polimeri, Compositi e Biomateriali - IPCB
Aliphatic-aromatic polyesters
Poly(ethylene terephthalate)
Poly(trimethylene terephthalate)
MALDI
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/351831
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact