In preparation for the upcoming deuterium-tritium campaign at the JET tokamak, the ex-vessel fission chamber neutron diagnostics and the neutron activation system will be calibrated in absolute terms at 14 MeV neutron energy, to a required accuracy of less than 10%. Two nominally identical DT neutron generators were chosen as the calibration sources, both of which were fully calibrated and characterized at the UK's National Physical Laboratory. The neutron activation method was adopted as a complementary method for the purpose of determining the absolute value of the neutron yield from the neutron generators and to provide a means of cross check for the active detection methods being employed. The work being presented here shows the derivation of the neutron emission rate from the neutron generators based upon experimental activation foil measurements.

Activation measurements in support of the 14 MeV neutron calibration of T JET neutron monitors

L Giacomelli;M Rebai;D Rigamonti;M Tardocchi;
2017

Abstract

In preparation for the upcoming deuterium-tritium campaign at the JET tokamak, the ex-vessel fission chamber neutron diagnostics and the neutron activation system will be calibrated in absolute terms at 14 MeV neutron energy, to a required accuracy of less than 10%. Two nominally identical DT neutron generators were chosen as the calibration sources, both of which were fully calibrated and characterized at the UK's National Physical Laboratory. The neutron activation method was adopted as a complementary method for the purpose of determining the absolute value of the neutron yield from the neutron generators and to provide a means of cross check for the active detection methods being employed. The work being presented here shows the derivation of the neutron emission rate from the neutron generators based upon experimental activation foil measurements.
2017
Istituto di fisica del plasma - IFP - Sede Milano
Inglese
125
749
753
http://dx.doi.org/10.1016/j.fusengdes.2017.10.024
Sì, ma tipo non specificato
gamma-ray spectroscopy
neutron activation
tokamak absolute neutron calibration
Germanium detectors
20
info:eu-repo/semantics/article
262
Jednorog, S; Laszynska, E; Batistoni, P; Bienkowska, B; Cufar, A; Ghani, Z; Giacomelli, L; Klix, A; Loreti, S; Mikszuta, K; Packer, L; Peacock, A; Pil...espandi
01 Contributo su Rivista::01.01 Articolo in rivista
restricted
   Implementation of activities described in the Roadmap to Fusion during Horizon 2020 through a Joint programme of the members of the EUROfusion consortium
   EUROfusion
   H2020
   633053
File in questo prodotto:
File Dimensione Formato  
prod_395056-doc_136821.pdf

solo utenti autorizzati

Descrizione: Articolo pubblicato
Tipologia: Versione Editoriale (PDF)
Dimensione 1.04 MB
Formato Adobe PDF
1.04 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/351982
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 13
social impact