SPIDER is the prototype beam source of the ITER Heating Neutral Beam injector. A movable diagnostic calorimeter will be used as a direct mean to obtain the beam footprint in short-pulses, while a fixed beam-dump is installed for steady-state operation. For the comparison between experiment and numerical simulations of ion beam extraction, measuring the beam emittance is extremely useful, being the most complete characterization for a particle beam. We discuss in this paper two proposals for beam-emittance measurements in SPIDER: at high beam energies, a fixed electric-sweep scanner is proposed for integration in the water-cooled beam-dump; at relatively low beam energies, a movable emittance scanner is proposed for the installation on the movable diagnostic calorimeter. The synthetic signals of the scanner are calculated considering the multibeamlet setup. The constraints given by the integration in high heat load components and the thermal design are discussed. The fixed ESS can be used to reconstruct the beam divergence, even if it detects only a limited section of the beamlet emittance, if identical single-beamlet optics is assumed. The movable emittance scanner is easy to integrate in the present design, and allows a full characterization of the single beamlet optics.

Study for Emittance Measurements in a High-Current Multibeamlet Beam

Zaupa Matteo;Serianni Gianluigi;Pasqualotto Roberto
2018

Abstract

SPIDER is the prototype beam source of the ITER Heating Neutral Beam injector. A movable diagnostic calorimeter will be used as a direct mean to obtain the beam footprint in short-pulses, while a fixed beam-dump is installed for steady-state operation. For the comparison between experiment and numerical simulations of ion beam extraction, measuring the beam emittance is extremely useful, being the most complete characterization for a particle beam. We discuss in this paper two proposals for beam-emittance measurements in SPIDER: at high beam energies, a fixed electric-sweep scanner is proposed for integration in the water-cooled beam-dump; at relatively low beam energies, a movable emittance scanner is proposed for the installation on the movable diagnostic calorimeter. The synthetic signals of the scanner are calculated considering the multibeamlet setup. The constraints given by the integration in high heat load components and the thermal design are discussed. The fixed ESS can be used to reconstruct the beam divergence, even if it detects only a limited section of the beamlet emittance, if identical single-beamlet optics is assumed. The movable emittance scanner is easy to integrate in the present design, and allows a full characterization of the single beamlet optics.
2018
Istituto gas ionizzati - IGI - Sede Padova
Inglese
13
3405092-1
3405092-4
4
http://www.jspf.or.jp/PFR/PDF2018/pfr2018_13-3405092
Sì, ma tipo non specificato
TER Neutral Beam Injector
beam emittance
multibeamlet
negative hydrogen ion beam
SPIDER
Article Number: 3405092 / This work was set up with partial financial support of F4E.
2
info:eu-repo/semantics/article
262
Sartori Emanuele; Zaupa Matteo; Serianni Gianluigi; Pasqualotto Roberto
01 Contributo su Rivista::01.01 Articolo in rivista
none
   EU Fusion for ITER Applications
   EUFORIA
   FP7
   211804
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/352554
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact