The use of caesium vapour is mandatory in plasma sources for negative ion beams to achieve a sufficient negative ion density. In the SPIDER ion source, three caesium ovens will provide a sufficiently high caesium flux to the walls of the ion source, but also a relatively even caesium distribution in the ion source volume. In order to qualify the caesium ovens in terms of repeatability of the evaporated caesium flow, and to characterize the caesium flux emitted from its nozzle, a set of diagnostics was installed in the small test facility CAesium Test Facility (CATS). This paper reports on the present configuration of the diagnostic set-up. Surface ionization probes are installed in front of the nozzle apertures. Movable surface ionization detectors are used to reconstruct the angular distribution of the emission. A quartz microbalance is installed at a fixed position, to provide the cumulated caesium over time. Finally, the laser absorption spectroscopy measures the line-integrated caesium density. An example of combined measurement is presented.

Diagnostics of Caesium emission from SPIDER caesium oven prototype

Barbisan M;Ghiraldelli R;Pasqualotto R;Serianni G
2018

Abstract

The use of caesium vapour is mandatory in plasma sources for negative ion beams to achieve a sufficient negative ion density. In the SPIDER ion source, three caesium ovens will provide a sufficiently high caesium flux to the walls of the ion source, but also a relatively even caesium distribution in the ion source volume. In order to qualify the caesium ovens in terms of repeatability of the evaporated caesium flow, and to characterize the caesium flux emitted from its nozzle, a set of diagnostics was installed in the small test facility CAesium Test Facility (CATS). This paper reports on the present configuration of the diagnostic set-up. Surface ionization probes are installed in front of the nozzle apertures. Movable surface ionization detectors are used to reconstruct the angular distribution of the emission. A quartz microbalance is installed at a fixed position, to provide the cumulated caesium over time. Finally, the laser absorption spectroscopy measures the line-integrated caesium density. An example of combined measurement is presented.
2018
Istituto gas ionizzati - IGI - Sede Padova
9780735417809
SPIDER
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/353104
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? ND
social impact