Grazing-incidence X-ray fluorescence measurements were applied for a time-resolved study of an organic memristor conductivity variation mechanism. A comparison of these results with electrical measurements has allowed us to conclude that the variation of the fluorescence intensity of Rb ions is directly connected to the ionic charge transferred between the conducting polymer and the solid electrolyte, which made up the device. In addition, the conductivity of the memristor was shown to be a function of the transferred ionic charge. © 2009 American Chemical Society.

Electrochemical control of the conductivity in an organic memristor: A time-resolved X-ray fluorescence study of ionic drift as a function of the applied voltage

Erokhin Victor;Erokhin Victor;
2009

Abstract

Grazing-incidence X-ray fluorescence measurements were applied for a time-resolved study of an organic memristor conductivity variation mechanism. A comparison of these results with electrical measurements has allowed us to conclude that the variation of the fluorescence intensity of Rb ions is directly connected to the ionic charge transferred between the conducting polymer and the solid electrolyte, which made up the device. In addition, the conductivity of the memristor was shown to be a function of the transferred ionic charge. © 2009 American Chemical Society.
2009
conducting polymer
organic memristor
polyaniline
solid electrolyte
X-ray fluorescence
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/357945
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 92
  • ???jsp.display-item.citation.isi??? ND
social impact