This paper describes the architecture of DIscMC, an interactive system wich supports insosurfacing on regular volume datasets. DIScMc adopts a discretized fitting algorithm that, considerably reduces the number of polygons generated by a Marching Cubes-Like scheme while presenting shorter running times, The extracted surfaces are composedof polygons lying within a finite number of incidences, thus allowing simple merging of thc output Iacets into large coplanar triangular fects. A pyramidal rapresentation of the volume dataset has been adoptedd to speed-up isosurface fitting, by avoiding empty volume traversal, and to support multiple level of resolution fitting. The systern has been implemented in a Unix environment, using a de facto standard graphics library. The functionalities and the user interface of the system are dscribed in detail.

Viene presentata una nuova tecnica a microonde (MIPOR, Brevetto CNR-ENEL FI/93/A231) per misure di concentrazione in flussi bifase aria-carbone. Il metodo è basato sulla dipendenza dello sfasamento di microonde che viaggiano in un mezzo dalla costante dielettrica di quest'ultimo. Si tratta di una tecnica di misura non ivasiva, che consente di ovviare ai grossi problemi di erosione tipici di strumentazione inserita all'interno dei condotti di trasporto. Il metodo non è di tipo assoluto, per cui lo strumento necessita di una procedura di calibrazione prima dell'impiego. In fase di utilizzo dello strumento, la misura di portata in massa di carbone può essere ottenuta a partire dal dato di concentrazione e dalla portata di aria di trasporto. L'articolo riporta una breve descrizione del metodo e dello strumento, seguita dalla presentazione dei primi risultati sperimentali ottenuti dal CISE con uno strumento prototipo funzionante ad una frequenza di 10 GHz. Il polverino di carbone è stato trasportato in fase diluita in un condotto di diametro interno pari a 80 mm. La velocità media dell'aria di trasporto è stata mantenuta costante durante le prove e compresa tra 20 e 25 m/s; le concentrazioni realizzate (in termini di rapporto tra la portata in massa di polverino e quella di aria di trasporto) sono comprese tra 0 e 1.2. Il circuito sperimentale è dotato di misure indipendenti di portata di aria e di solido, che hanno costituito il riferimento per la calibrazione del sistema di misura a microonde.

A non-invasive microwave density sensor for pneumatic transport lines

1996

Abstract

This paper describes the architecture of DIscMC, an interactive system wich supports insosurfacing on regular volume datasets. DIScMc adopts a discretized fitting algorithm that, considerably reduces the number of polygons generated by a Marching Cubes-Like scheme while presenting shorter running times, The extracted surfaces are composedof polygons lying within a finite number of incidences, thus allowing simple merging of thc output Iacets into large coplanar triangular fects. A pyramidal rapresentation of the volume dataset has been adoptedd to speed-up isosurface fitting, by avoiding empty volume traversal, and to support multiple level of resolution fitting. The systern has been implemented in a Unix environment, using a de facto standard graphics library. The functionalities and the user interface of the system are dscribed in detail.
1996
Istituto di Scienza e Tecnologie dell'Informazione "Alessandro Faedo" - ISTI
Viene presentata una nuova tecnica a microonde (MIPOR, Brevetto CNR-ENEL FI/93/A231) per misure di concentrazione in flussi bifase aria-carbone. Il metodo è basato sulla dipendenza dello sfasamento di microonde che viaggiano in un mezzo dalla costante dielettrica di quest'ultimo. Si tratta di una tecnica di misura non ivasiva, che consente di ovviare ai grossi problemi di erosione tipici di strumentazione inserita all'interno dei condotti di trasporto. Il metodo non è di tipo assoluto, per cui lo strumento necessita di una procedura di calibrazione prima dell'impiego. In fase di utilizzo dello strumento, la misura di portata in massa di carbone può essere ottenuta a partire dal dato di concentrazione e dalla portata di aria di trasporto. L'articolo riporta una breve descrizione del metodo e dello strumento, seguita dalla presentazione dei primi risultati sperimentali ottenuti dal CISE con uno strumento prototipo funzionante ad una frequenza di 10 GHz. Il polverino di carbone è stato trasportato in fase diluita in un condotto di diametro interno pari a 80 mm. La velocità media dell'aria di trasporto è stata mantenuta costante durante le prove e compresa tra 20 e 25 m/s; le concentrazioni realizzate (in termini di rapporto tra la portata in massa di polverino e quella di aria di trasporto) sono comprese tra 0 e 1.2. Il circuito sperimentale è dotato di misure indipendenti di portata di aria e di solido, che hanno costituito il riferimento per la calibrazione del sistema di misura a microonde.
ANIMP
File in questo prodotto:
File Dimensione Formato  
prod_411556-doc_144935.pdf

solo utenti autorizzati

Descrizione: A non-invasive microwave density sensor for pneumatic transport lines
Tipologia: Versione Editoriale (PDF)
Dimensione 1.99 MB
Formato Adobe PDF
1.99 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/360530
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact