Background and objective Patients affected by systemic sclerosis (SSc) develop functional and structural microcirculatory dysfunction, which progressively evolves towards systemic tissue fibrosis (sclerosis). Disease initially affects distal extremities, which become preferential sites of diagnostic scrutiny. This pilot investigation tested the hypothesis that peripheral microcirculatory dysfunction in SSc could be non-invasively assessed by 2D Near Infrared Spectroscopic (NIRS) imaging of the hand associated with Vascular Occlusion Testing (VOT). NIRS allows measurement of hemoglobin oxygen saturation (StO) in the blood perfusing the volume tissue under scrutiny. Methods In five normal volunteers and five SSc patients we applied a multispectral oximetry imaging device (Kent camera, Kent Imaging, Calgary, Canada) to acquire StO 2D maps of the whole hand palm during baseline, ischemia and reperfusion phase. Results We found significant differences between controls and SSc patients in basal StO (82.80 ± 2.51 vs 65.44 ± 7.96%, p = 0.0016), minimum StO (59.35 ± 4.29 vs 40.73 ± 6.47%, p = 0.0007), final StO (83.83 ± 4.09 vs 68.84 ± 11.41%, p = 0.02) and time to maximum StO (40 ± 12.25 vs 62 ± 4.47 s, p = 0.005). Conclusions This is, to our knowledge, the first application of 2D NIRS imaging of the whole hand to the investigation of microvascular dysfunction in systemic sclerosis. The image processing presented here considered the StO in the entire hand allowing a comprehensive view of the spatial heterogeneity of microvascular dysfunction.
Assessment of hand superficial oxygenation during ischemia/reperfusion in healthy subjects versus systemic sclerosis patients by 2D near infrared spectroscopic imaging
Jalil B;Hartwig V;Salvetti O;Gargani L;L'Abbate A
2018
Abstract
Background and objective Patients affected by systemic sclerosis (SSc) develop functional and structural microcirculatory dysfunction, which progressively evolves towards systemic tissue fibrosis (sclerosis). Disease initially affects distal extremities, which become preferential sites of diagnostic scrutiny. This pilot investigation tested the hypothesis that peripheral microcirculatory dysfunction in SSc could be non-invasively assessed by 2D Near Infrared Spectroscopic (NIRS) imaging of the hand associated with Vascular Occlusion Testing (VOT). NIRS allows measurement of hemoglobin oxygen saturation (StO) in the blood perfusing the volume tissue under scrutiny. Methods In five normal volunteers and five SSc patients we applied a multispectral oximetry imaging device (Kent camera, Kent Imaging, Calgary, Canada) to acquire StO 2D maps of the whole hand palm during baseline, ischemia and reperfusion phase. Results We found significant differences between controls and SSc patients in basal StO (82.80 ± 2.51 vs 65.44 ± 7.96%, p = 0.0016), minimum StO (59.35 ± 4.29 vs 40.73 ± 6.47%, p = 0.0007), final StO (83.83 ± 4.09 vs 68.84 ± 11.41%, p = 0.02) and time to maximum StO (40 ± 12.25 vs 62 ± 4.47 s, p = 0.005). Conclusions This is, to our knowledge, the first application of 2D NIRS imaging of the whole hand to the investigation of microvascular dysfunction in systemic sclerosis. The image processing presented here considered the StO in the entire hand allowing a comprehensive view of the spatial heterogeneity of microvascular dysfunction.File | Dimensione | Formato | |
---|---|---|---|
prod_417033-doc_151161.pdf
non disponibili
Descrizione: Assessment of hand superficial oxygenation during ischemia/reperfusion in healthy subjects versus systemic sclerosis patients
Tipologia:
Versione Editoriale (PDF)
Dimensione
3.51 MB
Formato
Adobe PDF
|
3.51 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.