The objective of this work was to determine the partitioning of the pollutant load in urban wastewater in order to improve the conventional sewage treatment. In addition to settling tests, physical fractionation of COD in the degritted influent of Roma-Nord sewage treatment plant was performed via sequential filtration through sieves and membrane filters of the following pore size: 150-100-50-25-1-0.2 ?m, and 100 kD (about 0.02 ?m). Biodegradability studies were also performed on the different size fractions. Size fractionation showed that COD in Roma-Nord sewage is predominantly associated with settleable and supracolloidal (> 1 ?m) particles, each size range including about 40% of total COD. Biodegradability tests indicated that the large fraction of COD associated with supracolloidal particles, which are not removed in the primary treatment, is characterised by slow degradability. This suggests that removal of these particles prior to biological treatment may greatly improve the overall treatment scheme. Preliminary pilot plant coagulation tests with lime at pH 9 showed that lime-enhanced primary treatment may increase COD removal efficiencies from typical 30-35% up to 65-70%, by inducing almost complete removal of the COD fraction associated with supracolloidal particles.

Size fractionation of COD in urban wastewater from a combined sewer system

MARANI D;RAMADORI R;BRAGUGLIA CM
2004

Abstract

The objective of this work was to determine the partitioning of the pollutant load in urban wastewater in order to improve the conventional sewage treatment. In addition to settling tests, physical fractionation of COD in the degritted influent of Roma-Nord sewage treatment plant was performed via sequential filtration through sieves and membrane filters of the following pore size: 150-100-50-25-1-0.2 ?m, and 100 kD (about 0.02 ?m). Biodegradability studies were also performed on the different size fractions. Size fractionation showed that COD in Roma-Nord sewage is predominantly associated with settleable and supracolloidal (> 1 ?m) particles, each size range including about 40% of total COD. Biodegradability tests indicated that the large fraction of COD associated with supracolloidal particles, which are not removed in the primary treatment, is characterised by slow degradability. This suggests that removal of these particles prior to biological treatment may greatly improve the overall treatment scheme. Preliminary pilot plant coagulation tests with lime at pH 9 showed that lime-enhanced primary treatment may increase COD removal efficiencies from typical 30-35% up to 65-70%, by inducing almost complete removal of the COD fraction associated with supracolloidal particles.
2004
Istituto di Ricerca Sulle Acque - IRSA
Coagulation
filtration
particulate size
sewage
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/36397
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact