The NIO1 (Negative Ion Optimization phase 1) source can provide continuous beam operation, which is convenient for systematic parameter and equipment studies. Even in the pure volume production regime, the source yield was found to depend on conditioning procedures. Magnetic configuration tests continued adding magnets to the existing setup; the filter field component Bx has been progressively extended to span the-12 to 5 mT range, and as a trend, source performances improved with |Bx|. The progress of camera beam diagnostics and of the quality of the volume-produced H-beam is also shown. The status, off-line results, and reliability of a first NIO1 cesium oven are discussed;other upgrades in preparation (cavity ring down spectrometer, the end calorimeter, and conceptual tests of the energy recovery system) are also listed.

Beam and installation improvements of the NIO1 ion source

Barbisan M;Agostini M;Antoni V;Cervaro V;Maniero M;Recchia M;Serianni G;Taccogna F;
2020

Abstract

The NIO1 (Negative Ion Optimization phase 1) source can provide continuous beam operation, which is convenient for systematic parameter and equipment studies. Even in the pure volume production regime, the source yield was found to depend on conditioning procedures. Magnetic configuration tests continued adding magnets to the existing setup; the filter field component Bx has been progressively extended to span the-12 to 5 mT range, and as a trend, source performances improved with |Bx|. The progress of camera beam diagnostics and of the quality of the volume-produced H-beam is also shown. The status, off-line results, and reliability of a first NIO1 cesium oven are discussed;other upgrades in preparation (cavity ring down spectrometer, the end calorimeter, and conceptual tests of the energy recovery system) are also listed.
2020
Istituto per la Scienza e Tecnologia dei Plasmi - ISTP
Inglese
91
1
013316-1
013316-5
5
https://aip.scitation.org/doi/10.1063/1.5128658
Sì, ma tipo non specificato
Ion sources
Negative ions
Light measurement
Beam diagnostics
Cavity ring down
Continuous beams
End calorimeters
Energy recovery system
Field components
Magnetic configuration
Volume production
Article Number 013316 / Electronic ISSN: 1089-7623 / Published Online: 16 January 2020 / http://www.scopus.com/inward/record.url?eid=2-s2.0-85078440391&partnerID=q2rCbXpz / Some parts of this research were financially supported by EUROFusion, commission INFN-5 (technological researches) or project INFN-E (energy).
29
info:eu-repo/semantics/article
262
Cavenago, M; Barbisan, M; Delogu, R; Pimazzoni, A; Poggi, C; Ugoletti, M; Agostini, M; Antoni, V; Baltador, C; Cervaro, V; De Muri, M; Giora, D; Jain,...espandi
01 Contributo su Rivista::01.01 Articolo in rivista
restricted
   Implementation of activities described in the Roadmap to Fusion during Horizon 2020 through a Joint programme of the members of the EUROfusion consortium
   EUROfusion
   H2020
   633053
File in questo prodotto:
File Dimensione Formato  
prod_416620-doc_146858.pdf

solo utenti autorizzati

Descrizione: Beam and installation improvements of theNIO1 ion source
Tipologia: Versione Editoriale (PDF)
Dimensione 3.9 MB
Formato Adobe PDF
3.9 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/364328
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 8
social impact