Membrane bioreactors allow for higher sludge concentrations and improved degradation efficiencies with respect to conventional activated sludge. However, in the current practice these systems are often operated under sub-optimal conditions, since so far no precise indications have yet been issued on the optimal operating conditions of MBR for municipal wastewater treatment. This paper reports some results of four years of operation of a bench scale membrane bioreactor where steady state conditions were investigated under different sludge retention times. The whole experimental campaign was oriented towards the investigation of optimal process conditions in terms of COD removal and nitrification, biomass activity and growth, and sludge characteristics. The membrane bioreactor treated real municipal sewage, and four different sludge ages were tested ( 20, 40, 60, and 80 days) and compared with previous data on complete sludge retention. The results showed that the the biology of the system, as assessed by the oxygen uptake rate, is less affected than the sludge physical parameters. In particular, although the growth yield was observed to dramatically drop for SRT higher than 80 days, the biological activity was maintained under all the tested conditions. These considerations suggest that high SRT are convenient in terms of limited excess sludge production without losses of the treatment capacity. Physical characteristics such as the viscosity and the filterability appear to be negatively affected by prolonged sludge retention times, but their values remain within the ranges normally reported for conventional activated sludge.

OPTIMAL SLUDGE RETENTION TIME FOR A BENCH SCALE MBR TREATING MUNICIPAL SEWAGE

POLLICE A;LAERA G;
2008

Abstract

Membrane bioreactors allow for higher sludge concentrations and improved degradation efficiencies with respect to conventional activated sludge. However, in the current practice these systems are often operated under sub-optimal conditions, since so far no precise indications have yet been issued on the optimal operating conditions of MBR for municipal wastewater treatment. This paper reports some results of four years of operation of a bench scale membrane bioreactor where steady state conditions were investigated under different sludge retention times. The whole experimental campaign was oriented towards the investigation of optimal process conditions in terms of COD removal and nitrification, biomass activity and growth, and sludge characteristics. The membrane bioreactor treated real municipal sewage, and four different sludge ages were tested ( 20, 40, 60, and 80 days) and compared with previous data on complete sludge retention. The results showed that the the biology of the system, as assessed by the oxygen uptake rate, is less affected than the sludge physical parameters. In particular, although the growth yield was observed to dramatically drop for SRT higher than 80 days, the biological activity was maintained under all the tested conditions. These considerations suggest that high SRT are convenient in terms of limited excess sludge production without losses of the treatment capacity. Physical characteristics such as the viscosity and the filterability appear to be negatively affected by prolonged sludge retention times, but their values remain within the ranges normally reported for conventional activated sludge.
2008
Istituto di Ricerca Sulle Acque - IRSA
Istituto di Ricerca Sulle Acque - IRSA
Activity; Biomass yield; Filterability; Membrane bioreactors; Municipal sewage; Sludge retention time
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/36469
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 26
social impact