The time synchronization of smart grid devices is a critical feature for the successful application of advanced grid monitoring and control techniques. Synchronization mechanisms based on the accurate estimation of the Time of Arrival (ToA) of network messages-sent over power line cables-are a promising solution to achieve synchronization tasks over distribution lines. In this paper, a chirp-based synchronization technique over the Medium Voltage (MV) grid has been proposed and characterized. Such approach has the benefit of not requiring the installation of a dedicated infrastructure, thanks to the exploitation of power distribution lines for the transmission of time synchronization data. The effectiveness of the approach has been experimentally evaluated on a simplified MV line available in a testing laboratory. Although, the tested chirp has a limited frequency bandwidth (80 kHz), the maximum variation of the ToA estimation is on the order of 3.5 ?s, which fulfills the requirements of most smart grid applications.

An experimental characterization of time of arrival accuracy for time synchronization of medium voltage smart grid solutions

A Flammini;D Di Cara;N Panzavecchia;
2019

Abstract

The time synchronization of smart grid devices is a critical feature for the successful application of advanced grid monitoring and control techniques. Synchronization mechanisms based on the accurate estimation of the Time of Arrival (ToA) of network messages-sent over power line cables-are a promising solution to achieve synchronization tasks over distribution lines. In this paper, a chirp-based synchronization technique over the Medium Voltage (MV) grid has been proposed and characterized. Such approach has the benefit of not requiring the installation of a dedicated infrastructure, thanks to the exploitation of power distribution lines for the transmission of time synchronization data. The effectiveness of the approach has been experimentally evaluated on a simplified MV line available in a testing laboratory. Although, the tested chirp has a limited frequency bandwidth (80 kHz), the maximum variation of the ToA estimation is on the order of 3.5 ?s, which fulfills the requirements of most smart grid applications.
2019
Istituto di iNgegneria del Mare - INM (ex INSEAN)
9781728100753
Chirp modulation
Medium Voltage Distribution Grid
Performance Evalua
Smart Grid
Time of Arrival
Time Synchronization
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/365046
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact