The Santa Maria di Collemaggio Basilica is an important cultural heritage site and exemplifies Romanesque-Gothic art in the Abruzzo region (central Italy). Erected in the second half of the XII century, the Basilica was severely damaged during the April 6, 2009 L'Aquila earthquake (M-w 6.1). In particular, the area of the transept collapsed causing the dome to fall. A refined two-dimensional (2D) geotechnical model was built representing a section that includes the Basilica, in order to better understand the soil response of the Basilica site. The subsoil model was constrained using the geophysical and geotechnical data collected from the seismic microzonation studies, the reconstruction of private damaged buildings and other technical and scientific studies realized in the L'Aquila basin and in the area of the Basilica before and after L'Aquila earthquake. 2D site response analyses were performed to verify the presence of local site effects by comparing simulated versus experimental transfer functions. Moreover, a frequency-wavenumber (f-k) analysis was executed with the aim of evaluating the occurrence of surface waves generated within the basin. 2D seismic effects involve significant amplification in the period range of engineering interest, therein providing an appropriate elastic response spectrum for the restoration of the Basilica.

2D site response analysis of a cultural heritage: the case study of the site of Santa Maria di Collemaggio Basilica (L'Aquila, Italy)

Gaudiosi Iolanda;
2018

Abstract

The Santa Maria di Collemaggio Basilica is an important cultural heritage site and exemplifies Romanesque-Gothic art in the Abruzzo region (central Italy). Erected in the second half of the XII century, the Basilica was severely damaged during the April 6, 2009 L'Aquila earthquake (M-w 6.1). In particular, the area of the transept collapsed causing the dome to fall. A refined two-dimensional (2D) geotechnical model was built representing a section that includes the Basilica, in order to better understand the soil response of the Basilica site. The subsoil model was constrained using the geophysical and geotechnical data collected from the seismic microzonation studies, the reconstruction of private damaged buildings and other technical and scientific studies realized in the L'Aquila basin and in the area of the Basilica before and after L'Aquila earthquake. 2D site response analyses were performed to verify the presence of local site effects by comparing simulated versus experimental transfer functions. Moreover, a frequency-wavenumber (f-k) analysis was executed with the aim of evaluating the occurrence of surface waves generated within the basin. 2D seismic effects involve significant amplification in the period range of engineering interest, therein providing an appropriate elastic response spectrum for the restoration of the Basilica.
2018
Istituto di Geologia Ambientale e Geoingegneria - IGAG
L'Aquila earthquake
2D site response analysis
Site effects
Geotechnical model
Aftershocks records
Cultural heritage
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/365908
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 12
social impact