Oxide nanoparticles are widely studied because of their unique properties, including their crystalline phase, surface area, and porosity, which make them attractive for several applications. These properties are related to the increase in the surface/volume ratio when moving from the bulk to the nanoscale. For this reason, a diagnostic tool capable of monitoring the nanoparticle size and concentration during synthesis is particularly valuable. The laser-induced incandescence technique is widely used to provide such information. This study explored the applicability of this technique to TiO nanoparticles in flame spray synthesis. The fluorescence, flame emission, and incandescence signals were investigated. Time-resolved spectral measurements were first carried out on TiO nanoparticles deposited on a filter. At low laser fluences, the fluorescence signal of anatase TiO nanoparticles was detected. At higher fluences, the incandescence signal appeared. A fluence threshold limit that depended on the matrix effect was observed, above which breakdown phenomena occur. Then, laser-induced incandescence spectral measurements were performed on the flame spray at different heights above the burner and different acquisition delay times. The analysis showed the applicability and challenges in using this diagnostic tool in flame spray synthesis.

Laser-induced emission of TiO2 nanoparticles in flame spray synthesis

De Iuliis S;Migliorini F;
2019

Abstract

Oxide nanoparticles are widely studied because of their unique properties, including their crystalline phase, surface area, and porosity, which make them attractive for several applications. These properties are related to the increase in the surface/volume ratio when moving from the bulk to the nanoscale. For this reason, a diagnostic tool capable of monitoring the nanoparticle size and concentration during synthesis is particularly valuable. The laser-induced incandescence technique is widely used to provide such information. This study explored the applicability of this technique to TiO nanoparticles in flame spray synthesis. The fluorescence, flame emission, and incandescence signals were investigated. Time-resolved spectral measurements were first carried out on TiO nanoparticles deposited on a filter. At low laser fluences, the fluorescence signal of anatase TiO nanoparticles was detected. At higher fluences, the incandescence signal appeared. A fluence threshold limit that depended on the matrix effect was observed, above which breakdown phenomena occur. Then, laser-induced incandescence spectral measurements were performed on the flame spray at different heights above the burner and different acquisition delay times. The analysis showed the applicability and challenges in using this diagnostic tool in flame spray synthesis.
2019
Istituto di Chimica della Materia Condensata e di Tecnologie per l'Energia - ICMATE
Laser-Induced Incandescence
TiO2
Flame Spray Pyrolysis
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/366239
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 17
  • ???jsp.display-item.citation.isi??? ND
social impact