A high resolution neutron spectrometer (HRNS) system has been designed as a neutron diagnostic tool for ITER. The HRNS is dedicated to measurements of time resolved neutron energy spectra for both deuterium and deuterium-tritium (DT) plasmas. The main function of the HRNS is to determine the fuel ion ratio n t/n d in the plasma core with 20% uncertainty and a time resolution of 100 ms for a range of ITER operating scenarios from 0.5 MW to 500 MW in fusion power. Moreover, neutron spectroscopy measurements should also be possible in the initial deuterium phase of ITER experiments. A supplementary function of the HRNS is to provide information on the fuel ion temperature. Furthermore, the HRNS can be used as an additional line-of-sight (LOS) for the radial neutron camera. To meet these requirements, a set of four spectrometers positioned after each other along a single LOS has been designed. The detector techniques employed include a thin foil proton recoil spectrometer (TPR), a neutron diamond detector (NDD), a back-scattering time-of-flight system (bToF) and a forward time-of-flight system (fToF). The TPR system, positioned closest to the plasma, provides data at high fusion powers. For plasma conditions producing intermediate fusion power two neutron spectrometers are installed: NDD and bToF. The NDD is installed as the second instrument along the HRNS LOS after the TPR. The fToF spectrometer is dedicated for low tritium densities and pure deuterium operation. The paper summarizes the current state of the art of neutron spectroscopy useful in plasma diagnostics and the possibility of installing a dedicated HRNS for ITER in the designated diagnostic port. We conclude that the proposed HRNS system can fulfil the ITER measurement requirements over a broad range of plasma operational scenarios, including full power DT, start-up, ramp-down and pure D operations.

Conceptual design of the high resolution neutron spectrometer for ITER

Giacomelli Luca C;Tardocchi Marco;
2019

Abstract

A high resolution neutron spectrometer (HRNS) system has been designed as a neutron diagnostic tool for ITER. The HRNS is dedicated to measurements of time resolved neutron energy spectra for both deuterium and deuterium-tritium (DT) plasmas. The main function of the HRNS is to determine the fuel ion ratio n t/n d in the plasma core with 20% uncertainty and a time resolution of 100 ms for a range of ITER operating scenarios from 0.5 MW to 500 MW in fusion power. Moreover, neutron spectroscopy measurements should also be possible in the initial deuterium phase of ITER experiments. A supplementary function of the HRNS is to provide information on the fuel ion temperature. Furthermore, the HRNS can be used as an additional line-of-sight (LOS) for the radial neutron camera. To meet these requirements, a set of four spectrometers positioned after each other along a single LOS has been designed. The detector techniques employed include a thin foil proton recoil spectrometer (TPR), a neutron diamond detector (NDD), a back-scattering time-of-flight system (bToF) and a forward time-of-flight system (fToF). The TPR system, positioned closest to the plasma, provides data at high fusion powers. For plasma conditions producing intermediate fusion power two neutron spectrometers are installed: NDD and bToF. The NDD is installed as the second instrument along the HRNS LOS after the TPR. The fToF spectrometer is dedicated for low tritium densities and pure deuterium operation. The paper summarizes the current state of the art of neutron spectroscopy useful in plasma diagnostics and the possibility of installing a dedicated HRNS for ITER in the designated diagnostic port. We conclude that the proposed HRNS system can fulfil the ITER measurement requirements over a broad range of plasma operational scenarios, including full power DT, start-up, ramp-down and pure D operations.
2019
Istituto di fisica del plasma - IFP - Sede Milano
Inglese
59
6
14
Sì, ma tipo non specificato
thermonuclear fusion
ITER
neutron diagnostics
high resolution neutron spectrometry
fuel ion ratio
24
info:eu-repo/semantics/article
262
Scholz, Marek; Hjalmarsson, Anders; Hajduk, Leszek; Ericsson, Goran; Kotula, Jerzy; Woznicka, Urszula; Blocki, Jacek; Brichard, Benoit; Conroy, Sean; ...espandi
01 Contributo su Rivista::01.01 Articolo in rivista
restricted
   Implementation of activities described in the Roadmap to Fusion during Horizon 2020 through a Joint programme of the members of the EUROfusion consortium
   EUROfusion
   H2020
   633053
File in questo prodotto:
File Dimensione Formato  
prod_403008-doc_140213.pdf

solo utenti autorizzati

Descrizione: Articolo pubblicato
Tipologia: Versione Editoriale (PDF)
Dimensione 2.19 MB
Formato Adobe PDF
2.19 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/367889
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 23
  • ???jsp.display-item.citation.isi??? 21
social impact