The characterization of the X-ray energy spectrum during the high voltage conditioning of a multi electrode vacuum insulated system (such as the MITICA electrostatic accelerator) could be useful to understand which stage is causing the micro discharge onset. This technique seems particularly promising for measuring small dark currents (I< 10?A), which are generally difficult to be measured with standard techniques. The X-rays produced during HV experiments are mainly due to brems strahlung interaction between the electrons escaping from the HV electrodes (field emission effect) and the background gas or the chamber walls. The X-rays spectrum extends from low energy (~ keV) up to several hundreds of keV depending on the maximum potential difference applied to the electrodes. During these events high photon flux (about 1 MHz) has been measured in the last years using standard NaI detectors that are not able to cope with high rates. In order to measure this wide spectrum at high rate in single photon counting mode, a diagnostic system that combines a Gas Electron Multiplier (GEM) detector (active area 10x10cm2) and a LaBr3 scintillator (3"x3" active volume) coupled to standard photomultiplier (PMT) is under development. Both are able to stand very high rate (>MHz) in single photon counting mode and results to be complementary with respect to the X-rays energy: GEM is optimized to cover the energy range from 2 up to 50 keV, while LaBr3 extends from 50 keV up to 500 keV. The GEM detector is equipped with anodic pads (256 pads 6x6 mm2), readout with a new data acquisition system called GEMINI, which gives the possibility to obtain information about the energy deposited in the detector by the incoming radiation using the so called Time-Over-Threshold technique on each detector channel, allowing also a spatial reconstruction of the X-rays footprint. This measurement can be performed at several MHz counting rate, due to the very high rate capability of GEM detector (MHz/mm2). The LaBr3+PMT detector has a single readout channel that is routed to a 500 Msample/s ADC. This configuration allows getting a few percent energy resolution at 500 keV at MHz counting rate. This paper describes the system construction and shows preliminary measurements using laboratory source.

X-rays spectrum characterization during high voltage conditioning in vacuum insulated system using high rate detectors

Muraro A;Gorini G;Perelli Cippo E;Tardocchi M;Grosso G;Rigamonti D;Spagnolo S;Zuin M;Fincato M;Pasqualotto R;
2019

Abstract

The characterization of the X-ray energy spectrum during the high voltage conditioning of a multi electrode vacuum insulated system (such as the MITICA electrostatic accelerator) could be useful to understand which stage is causing the micro discharge onset. This technique seems particularly promising for measuring small dark currents (I< 10?A), which are generally difficult to be measured with standard techniques. The X-rays produced during HV experiments are mainly due to brems strahlung interaction between the electrons escaping from the HV electrodes (field emission effect) and the background gas or the chamber walls. The X-rays spectrum extends from low energy (~ keV) up to several hundreds of keV depending on the maximum potential difference applied to the electrodes. During these events high photon flux (about 1 MHz) has been measured in the last years using standard NaI detectors that are not able to cope with high rates. In order to measure this wide spectrum at high rate in single photon counting mode, a diagnostic system that combines a Gas Electron Multiplier (GEM) detector (active area 10x10cm2) and a LaBr3 scintillator (3"x3" active volume) coupled to standard photomultiplier (PMT) is under development. Both are able to stand very high rate (>MHz) in single photon counting mode and results to be complementary with respect to the X-rays energy: GEM is optimized to cover the energy range from 2 up to 50 keV, while LaBr3 extends from 50 keV up to 500 keV. The GEM detector is equipped with anodic pads (256 pads 6x6 mm2), readout with a new data acquisition system called GEMINI, which gives the possibility to obtain information about the energy deposited in the detector by the incoming radiation using the so called Time-Over-Threshold technique on each detector channel, allowing also a spatial reconstruction of the X-rays footprint. This measurement can be performed at several MHz counting rate, due to the very high rate capability of GEM detector (MHz/mm2). The LaBr3+PMT detector has a single readout channel that is routed to a 500 Msample/s ADC. This configuration allows getting a few percent energy resolution at 500 keV at MHz counting rate. This paper describes the system construction and shows preliminary measurements using laboratory source.
2019
Istituto di fisica del plasma - IFP - Sede Milano
Istituto gas ionizzati - IGI - Sede Padova
Istituto per la Scienza e Tecnologia dei Plasmi - ISTP
MITICA
X-rays spectrum
File in questo prodotto:
File Dimensione Formato  
prod_416358-doc_146727.pptx

solo utenti autorizzati

Descrizione: Slides Development of an X-ray detection system for the characterization of the high voltage conditioning
Tipologia: Versione Editoriale (PDF)
Dimensione 3.41 MB
Formato Microsoft Powerpoint XML
3.41 MB Microsoft Powerpoint XML   Visualizza/Apri   Richiedi una copia
prod_416358-doc_192902.pdf

solo utenti autorizzati

Descrizione: pdf slides Development of an X-ray detection system for the characterization of the high voltage conditioning
Tipologia: Versione Editoriale (PDF)
Dimensione 1.1 MB
Formato Adobe PDF
1.1 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/368578
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact