The X-IFU instrument of the ATHENA mission requires a set of thermal filters to reduce the photon shot noise onto its cryogenic detector and to protect it from molecular contamination. A set of five filters, operating at different nominal temperatures corresponding to the cryostat shield temperatures, is currently baselined. The knowledge of the actual filter temperature profiles is crucial to have a good estimation of the radiative load on the detector. Furthermore, a few filters may need to be warmed-up to remove contaminants and it is necessary to ensure that a threshold temperature is reached throughout the filters surface. For these reasons, it is fundamental to develop a thermal modeling of the full set of filters in a representative configuration. The baseline filter is a polyimide membrane 45 nm thick coated with 30 nm of highpurity aluminum, mechanically supported by a metallic honeycomb mesh. In this paper, we describe the implemented thermal modeling and report the results obtained in different studies: (i) a trade-off analysis on how to reach a minimum target temperature throughout the outer filter, (ii) a thermal analysis when varying the emissivity of the filter surfaces, and (iii) the effect of removing one of the filters.

Thermal modelling of the ATHENA X-IFU filters

D'Anca F;
2018

Abstract

The X-IFU instrument of the ATHENA mission requires a set of thermal filters to reduce the photon shot noise onto its cryogenic detector and to protect it from molecular contamination. A set of five filters, operating at different nominal temperatures corresponding to the cryostat shield temperatures, is currently baselined. The knowledge of the actual filter temperature profiles is crucial to have a good estimation of the radiative load on the detector. Furthermore, a few filters may need to be warmed-up to remove contaminants and it is necessary to ensure that a threshold temperature is reached throughout the filters surface. For these reasons, it is fundamental to develop a thermal modeling of the full set of filters in a representative configuration. The baseline filter is a polyimide membrane 45 nm thick coated with 30 nm of highpurity aluminum, mechanically supported by a metallic honeycomb mesh. In this paper, we describe the implemented thermal modeling and report the results obtained in different studies: (i) a trade-off analysis on how to reach a minimum target temperature throughout the outer filter, (ii) a thermal analysis when varying the emissivity of the filter surfaces, and (iii) the effect of removing one of the filters.
2018
Athena project
thermal filters
X-IFU instrument
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/370133
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? ND
social impact