The paper presents an acoustic pyrometry method for the reconstruction of temperature maps inside power plant boilers. It is based on measuring times-of-flight of acoustic waves along a number of straight paths in a cross-section of the boiler; via an integral relationship, these times depend on the temperature of the gaseous medium along the paths. On this basis, 2D temperature maps can be reconstructed using suitable inversion techniques. The structure of a particular system for the measurement of the times-of-flight is described, and two classes of reconstruction algorithms are presented. The algorithms proposed have been applied to both simulated and experimental data measured in power plants of the Italian National Electricity Board (ENEL). The results obtained appear fairly satisfactory, considering the small data sets that it was possible to acquire in the tested boilers. © 1996 IEEE.

An acoustic pyrometer system for tomographic thermal imaging in power plant boilers

Tonazzini A;
1996

Abstract

The paper presents an acoustic pyrometry method for the reconstruction of temperature maps inside power plant boilers. It is based on measuring times-of-flight of acoustic waves along a number of straight paths in a cross-section of the boiler; via an integral relationship, these times depend on the temperature of the gaseous medium along the paths. On this basis, 2D temperature maps can be reconstructed using suitable inversion techniques. The structure of a particular system for the measurement of the times-of-flight is described, and two classes of reconstruction algorithms are presented. The algorithms proposed have been applied to both simulated and experimental data measured in power plants of the Italian National Electricity Board (ENEL). The results obtained appear fairly satisfactory, considering the small data sets that it was possible to acquire in the tested boilers. © 1996 IEEE.
1996
Istituto di Scienza e Tecnologie dell'Informazione "Alessandro Faedo" - ISTI
acoustic pyrometer system
File in questo prodotto:
File Dimensione Formato  
prod_413441-doc_145558.pdf

solo utenti autorizzati

Descrizione: An acoustic pyrometer system for tomographic thermal imaging in power plant boilers
Tipologia: Versione Editoriale (PDF)
Dimensione 1.04 MB
Formato Adobe PDF
1.04 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/373740
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 187
  • ???jsp.display-item.citation.isi??? ND
social impact