This paper compares different provisions to protect a special high power switching power supply from internal shortfaults, in particular internal short-circuits. The power supply is based on a five three-phase NPC inverters, with common dclink, rated for a total power of about 60MW and for an output voltage of 6.5kV, using IGCTs as switching components. A large, distributed, capacitor bank is connected at the dc-link side of the inverters, with huge amount of stored energy, as high as 760kJ during nominal operation. In case of internal short-circuit of one inverter leg, due for example to a failure of one IGCT, this energy is discharged into the faulty leg, potentially leading to explosion and fault propagation. Simulations have been performed in order to analyze, select and design the most suitable protection to avoid this risk.

Protection From Internal Faults in a Special High Power Switching Conversion System for Thermonuclear Fusion Application

Gaio Elena;
2017

Abstract

This paper compares different provisions to protect a special high power switching power supply from internal shortfaults, in particular internal short-circuits. The power supply is based on a five three-phase NPC inverters, with common dclink, rated for a total power of about 60MW and for an output voltage of 6.5kV, using IGCTs as switching components. A large, distributed, capacitor bank is connected at the dc-link side of the inverters, with huge amount of stored energy, as high as 760kJ during nominal operation. In case of internal short-circuit of one inverter leg, due for example to a failure of one IGCT, this energy is discharged into the faulty leg, potentially leading to explosion and fault propagation. Simulations have been performed in order to analyze, select and design the most suitable protection to avoid this risk.
2017
Istituto gas ionizzati - IGI - Sede Padova
Inglese
Proceedings of the International Conference on Power Electronics and Drive Systems
2017 IEEE 12th International Conference on Power Electronics and Drive Systems (IEEE PEDS 2017)
252
258
7
978-1-5090-2364-6
http://www.rpsonline.com.sg/peds/IEEE%20PEDS%202017%20Programme.pdf
IEEE
New York
STATI UNITI D'AMERICA
December 12-15, 2017
Honolulu, Hawaii
Thermonuclear Fusion Application
Special High Power Switching Conversion System
The project F4E-OPE-278 Lot 1 has been funded with support from Fusion for Energy.
10
none
Zanotto, Loris; Dan, Mattia; Gaio, Elena; Gutierrez, Daniel; Decamps, Hans; Perna, Mauro; Falchi, Daniele; Finotti, Claudio; Panizza, Carlo; Premoli, ...espandi
273
info:eu-repo/semantics/conferenceObject
04 Contributo in convegno::04.01 Contributo in Atti di convegno
   EU Fusion for ITER Applications
   EUFORIA
   FP7
   211804
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/374101
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact