A microwave radiometer profiler is used to determine the no-attenuation level relative to which beacon atmospheric attenuation is measured. A technique that can be used for the discrimination of atmospheric conditions (clear-sky, cloudy, rainy) from the measured slant-path brightness temperatures is discussed, with the aim of improving the accuracy and the reliability of the radiometric correction.
Calibration and Use of Microwave Radiometers in Multiple-site EM Wave Propagation Experiments
L Luini;C Riva;R Nebuloni;M Mauri;
2018
Abstract
A microwave radiometer profiler is used to determine the no-attenuation level relative to which beacon atmospheric attenuation is measured. A technique that can be used for the discrimination of atmospheric conditions (clear-sky, cloudy, rainy) from the measured slant-path brightness temperatures is discussed, with the aim of improving the accuracy and the reliability of the radiometric correction.File in questo prodotto: