Models based on the multivariate partial least squares (PLS) regression technique are developed for the retrieval of phytoplankton size structure from measured light absorption spectra (BOUSSOLE site, northwestern Mediterranean Sea). PLS-models trained with data from the Mediterranean Sea showed good accuracy in retrieving, over the nine-year BOUSSOLE time series, the concentrations of total chlorophyll a [Tchl a], of the sum of seven diagnostic pigments and of pigments associated with micro, nano, and picophytoplankton size classes separately. PLS-models trained using either total particle or phytoplankton absorption spectra performed similarly, and both reproduced seasonal variations of biomass and size classes derived by high performance liquid chromatography. Satisfactory retrievals were also obtained using PLS-models trained with a data set including various locations of the world's oceans, with however a lower accuracy. These results open the way to an application of this method to absorption spectra derived from hyperspectral and field satellite radiance measurements. (C) 2013 Optical Society of America
Multivariate approach for the retrieval of phytoplankton size structure from measured light absorption spectra in the Mediterranean Sea (BOUSSOLE site)
Organelli Emanuele;
2013
Abstract
Models based on the multivariate partial least squares (PLS) regression technique are developed for the retrieval of phytoplankton size structure from measured light absorption spectra (BOUSSOLE site, northwestern Mediterranean Sea). PLS-models trained with data from the Mediterranean Sea showed good accuracy in retrieving, over the nine-year BOUSSOLE time series, the concentrations of total chlorophyll a [Tchl a], of the sum of seven diagnostic pigments and of pigments associated with micro, nano, and picophytoplankton size classes separately. PLS-models trained using either total particle or phytoplankton absorption spectra performed similarly, and both reproduced seasonal variations of biomass and size classes derived by high performance liquid chromatography. Satisfactory retrievals were also obtained using PLS-models trained with a data set including various locations of the world's oceans, with however a lower accuracy. These results open the way to an application of this method to absorption spectra derived from hyperspectral and field satellite radiance measurements. (C) 2013 Optical Society of AmericaI documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.