In the present study, we propose reflection FT-IR spectroscopy as non-invasive tool for monitoring cleaning residues from polychrome surfaces. Tests on simplified model paints allowed defining the analytical strengths both in term of selectivity and detection limits towards thickeners, surfactants and chelating agents most commonly used in cleaning formulations. Subsequently, the detection of these components has been assessed on aged paint mock-ups and an easel painting after cleaning with different gel formulations. The obtained results clearly proved the strengths of reflection FT-IR spectroscopy for a real time, non-invasive detection of cleaning residues on polychrome surfaces. Thickeners such as Klucel (R) G, surfactants including Ethomeen (R) C/12 and C/25 and chelating agents (citric acid + TEA, tetrasodium EDTA salt) were clearly detected after dry removal of the gels and in some tests also after the clearance step.
Non-invasive reflection FT-IR spectroscopy for on-site detection of cleaning system residues on polychrome surfaces
Rosi Francesca;Miliani Costanza;Cartechini LauraUltimo
Supervision
2020
Abstract
In the present study, we propose reflection FT-IR spectroscopy as non-invasive tool for monitoring cleaning residues from polychrome surfaces. Tests on simplified model paints allowed defining the analytical strengths both in term of selectivity and detection limits towards thickeners, surfactants and chelating agents most commonly used in cleaning formulations. Subsequently, the detection of these components has been assessed on aged paint mock-ups and an easel painting after cleaning with different gel formulations. The obtained results clearly proved the strengths of reflection FT-IR spectroscopy for a real time, non-invasive detection of cleaning residues on polychrome surfaces. Thickeners such as Klucel (R) G, surfactants including Ethomeen (R) C/12 and C/25 and chelating agents (citric acid + TEA, tetrasodium EDTA salt) were clearly detected after dry removal of the gels and in some tests also after the clearance step.| File | Dimensione | Formato | |
|---|---|---|---|
|
1-s2.0-S0026265X20307761-main.pdf
solo utenti autorizzati
Descrizione: File pdf
Tipologia:
Versione Editoriale (PDF)
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
5.88 MB
Formato
Adobe PDF
|
5.88 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
|
MICROC_105033_edit_report.pdf
Open Access dal 02/09/2022
Descrizione: versione accettata dell'articolo
Tipologia:
Documento in Post-print
Licenza:
Creative commons
Dimensione
1.27 MB
Formato
Adobe PDF
|
1.27 MB | Adobe PDF | Visualizza/Apri |
|
SI_Non invasive.pdf
accesso aperto
Descrizione: supporting information
Tipologia:
Altro materiale allegato
Licenza:
Altro tipo di licenza
Dimensione
3.59 MB
Formato
Adobe PDF
|
3.59 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.


