In F-19-MRI studies limiting factors are the presence of a low signal due to the low concentration of F-19-nuclei, necessary for biological applications, and the inherent low sensitivity of MRI. Hence, acquiring images using the pulse sequence with the best signal to noise ratio (SNR) by optimizing the acquisition parameters specifically to a F-19 compound is a core issue. In F-19-MRI, multiple-spin-echo (RARE) and gradient-echo (GRE) are the two most frequently used pulse sequence families; therefore we performed an optimization study of GRE pulse sequences based on numerical simulations and experimental acquisitions on fluorinated compounds. We compared GRE performance to an optimized RARE sequence. Images were acquired on a 7T MRI preclinical scanner on phantoms containing different fluorinated compounds Actual relaxation times (T-1, T-2, T-2*) were evaluated in order to predict SNR dependence on sequence parameters. Experimental comparisons between spoiled GRE and RARE, obtained at a fixed acquisition time and in steady state condition, showed RARE sequence outperforming the spoiled GRE (up to 406% higher). Conversely, the use of the unbalanced-SSFP showed a significant increase in SNR compared to RARE (up to 28% higher). Moreover, this sequence (as GRE in general) was confirmed to be virtually insensitive to T-1 and T-2 relaxation times, after proper optimization, thus improving marker independence from the biological environment.

Comparison between optimized GRE and RARE sequences for F-19 MRI studies

Mastropietro Alfonso;
2014

Abstract

In F-19-MRI studies limiting factors are the presence of a low signal due to the low concentration of F-19-nuclei, necessary for biological applications, and the inherent low sensitivity of MRI. Hence, acquiring images using the pulse sequence with the best signal to noise ratio (SNR) by optimizing the acquisition parameters specifically to a F-19 compound is a core issue. In F-19-MRI, multiple-spin-echo (RARE) and gradient-echo (GRE) are the two most frequently used pulse sequence families; therefore we performed an optimization study of GRE pulse sequences based on numerical simulations and experimental acquisitions on fluorinated compounds. We compared GRE performance to an optimized RARE sequence. Images were acquired on a 7T MRI preclinical scanner on phantoms containing different fluorinated compounds Actual relaxation times (T-1, T-2, T-2*) were evaluated in order to predict SNR dependence on sequence parameters. Experimental comparisons between spoiled GRE and RARE, obtained at a fixed acquisition time and in steady state condition, showed RARE sequence outperforming the spoiled GRE (up to 406% higher). Conversely, the use of the unbalanced-SSFP showed a significant increase in SNR compared to RARE (up to 28% higher). Moreover, this sequence (as GRE in general) was confirmed to be virtually insensitive to T-1 and T-2 relaxation times, after proper optimization, thus improving marker independence from the biological environment.
2014
F-19-MRI
sequence optimization
RARE
Gradient Echo
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/379441
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact