Objective: The aim of this study was to determine the effectiveness of a novel body-weight-supported (BWS) gait training system with visual feedback, called Copernicus® (Rehalife, Italy). This computerized device provides comfortable, regular and repeatable locomotion in hemiplegic patients. Through visual real-time monitoring of gait parameters, patients are trained to transfer weight loading alternately on both feet. Design: A single-blind, randomized controlled study. A single center used a computer-generated randomization code to allocate treatments. Setting: Intensive rehabilitation unit (IRU) at the Institute S. Anna (Italy). Participants: 63 first-ever stroke patients (39 men, age: 66.1 ± 9.6 years; 61.6 % with left-sided lesion) randomly distributed into three demographically/clinically matched groups. Treatments: All groups were treated five times a week for 2 -h sessions for six consecutive weeks. The first group ("control") underwent a conventional physical therapy; the second group performed advanced BWS gait training sessions without visual feedback (Experimental VF- group); whereas the third group used BWS with visual feedback stimulation (Experimental VF+ group). Main Outcome Measures: Absolute changes were recorded using conventional clinical scales and kinematic measurement of static gait balance from baseline to follow-up. Results: Significant interaction Group*Time effects scales (F2,126 = 5.1, p-level = 0.005, ?²p = 0.25; F2,126 = 4.7, p-level = 0.007, ?²p = 0.19; respectively) were detected in the Functional Independence Measure and Tinetti-Balance scales. Post hoc analysis demonstrated that the recovery of motor functioning was greater for the VF + group with respect to other groups (all p's <= 0.001). A similar pattern of findings was also obtained with a stabilometric analysis, demonstrating a better clinical improvement in static balance after VF + treatment. Conclusion: The proposed advanced rehabilitation system with visual feedback was more effective in improving gait recovery with respect to conventional and high-tech therapies without a sensor feedback.

A body-weight-supported visual feedback system for gait recovering in stroke patients: A randomized controlled study

Cerasa A
2020

Abstract

Objective: The aim of this study was to determine the effectiveness of a novel body-weight-supported (BWS) gait training system with visual feedback, called Copernicus® (Rehalife, Italy). This computerized device provides comfortable, regular and repeatable locomotion in hemiplegic patients. Through visual real-time monitoring of gait parameters, patients are trained to transfer weight loading alternately on both feet. Design: A single-blind, randomized controlled study. A single center used a computer-generated randomization code to allocate treatments. Setting: Intensive rehabilitation unit (IRU) at the Institute S. Anna (Italy). Participants: 63 first-ever stroke patients (39 men, age: 66.1 ± 9.6 years; 61.6 % with left-sided lesion) randomly distributed into three demographically/clinically matched groups. Treatments: All groups were treated five times a week for 2 -h sessions for six consecutive weeks. The first group ("control") underwent a conventional physical therapy; the second group performed advanced BWS gait training sessions without visual feedback (Experimental VF- group); whereas the third group used BWS with visual feedback stimulation (Experimental VF+ group). Main Outcome Measures: Absolute changes were recorded using conventional clinical scales and kinematic measurement of static gait balance from baseline to follow-up. Results: Significant interaction Group*Time effects scales (F2,126 = 5.1, p-level = 0.005, ?²p = 0.25; F2,126 = 4.7, p-level = 0.007, ?²p = 0.19; respectively) were detected in the Functional Independence Measure and Tinetti-Balance scales. Post hoc analysis demonstrated that the recovery of motor functioning was greater for the VF + group with respect to other groups (all p's <= 0.001). A similar pattern of findings was also obtained with a stabilometric analysis, demonstrating a better clinical improvement in static balance after VF + treatment. Conclusion: The proposed advanced rehabilitation system with visual feedback was more effective in improving gait recovery with respect to conventional and high-tech therapies without a sensor feedback.
2020
Istituto per la Ricerca e l'Innovazione Biomedica -IRIB
stroke
Gait rehabilitation
visual feedback
Body-weight-supported gait system
Sensor-feedback system
File in questo prodotto:
File Dimensione Formato  
prod_431953-doc_154442.pdf

solo utenti autorizzati

Descrizione: Paper Copernicus
Tipologia: Versione Editoriale (PDF)
Dimensione 1.48 MB
Formato Adobe PDF
1.48 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/380288
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact