The chiral separation of baclofen (Bac) was obtained by nano-liquid chromatography tandem mass spectrometry (nano-LC-MS/MS) using a 100 mu m I.D. fused silica capillary column packed with silica particles chemically modified with vancomycin. Various experimental parameters, such as composition (buffer concentration, water content, organic modifier) and pH of the mobile phase and sample solvent were investigated for method optimization. In order to increase the sensitivity an on -column focusing procedure was applied. Acceptable separation of Bac enantiomers was obtained in less than 11 min eluting in isocratic mode, with 90:10 MeOH/water (v/v) containing 10 mM ammonium acetate at pH 4.5. These optimized experimental conditions were applied to the analysis of human plasma samples spiked with racemic mixture of Bac. The use of a Buckypaper disc as sorbent membrane allows one to recover both enantiomers with yields > 65%. The method was fully validated, following the identification criteria of the European Commission Decision 2002/657/EC. (C) 2019 Elsevier B.V. All rights reserved.

Nano-liquid chromatography for enantiomers separation of baclofen by using vancomycin silica stationary phase

G D'Orazio;
2019

Abstract

The chiral separation of baclofen (Bac) was obtained by nano-liquid chromatography tandem mass spectrometry (nano-LC-MS/MS) using a 100 mu m I.D. fused silica capillary column packed with silica particles chemically modified with vancomycin. Various experimental parameters, such as composition (buffer concentration, water content, organic modifier) and pH of the mobile phase and sample solvent were investigated for method optimization. In order to increase the sensitivity an on -column focusing procedure was applied. Acceptable separation of Bac enantiomers was obtained in less than 11 min eluting in isocratic mode, with 90:10 MeOH/water (v/v) containing 10 mM ammonium acetate at pH 4.5. These optimized experimental conditions were applied to the analysis of human plasma samples spiked with racemic mixture of Bac. The use of a Buckypaper disc as sorbent membrane allows one to recover both enantiomers with yields > 65%. The method was fully validated, following the identification criteria of the European Commission Decision 2002/657/EC. (C) 2019 Elsevier B.V. All rights reserved.
2019
Istituto per i Sistemi Biologici - ISB (ex IMC)
Nano-liquid chromatography
Enantiomers
Chiral
Baclofen
Carbon nanotubes
Buckypaper
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/381583
Citazioni
  • ???jsp.display-item.citation.pmc??? ND