Graphene oxide (GO) coated electrodes provide an excellent platform for enzymatic glucose sensing, induced by the presence of glucose oxidase and an electrochemical transduction. Here, we show that the sensitivity of GO layers for glucose detection redoubles upon blending GO with chitosan (GO+Ch) and increases up to eight times if covalent binding of chitosan to GO (GO-Ch) is exploited. In addition, the conductivity of the composite material GO-Ch is suitable for electrochemical applications without the need of GO reduction, which is generally required for GO based coatings. Covalent modification of GO is achieved by a standard carboxylic activation/amidation approach by exploiting the abundant amino pendants of chitosan. Successful functionalization is proved by comparison with an ad-hoc synthesized control sample realized by using non-activated GO as precursor. The composite GO-Ch was deposited on standard screen-printed electrodes by a drop-casting approach. Comparison with a chitosan-GO blend and with pristine GO demonstrated the superior reliability and efficiency of the electrochemical response for glucose as a consequence of the high number of enzyme binding sites and of the partial reduction of GO during the carboxylic activation synthetic step.

Electrochemical sensing of glucose by chitosan modified graphene oxide

Favaretto Laura;Kovtun Alessandro;Treossi Emanuele;Corticelli Franco;Gazzano Massimo;Palermo Vincenzo;Zanardi Chiara;Melucci Manuela
2020

Abstract

Graphene oxide (GO) coated electrodes provide an excellent platform for enzymatic glucose sensing, induced by the presence of glucose oxidase and an electrochemical transduction. Here, we show that the sensitivity of GO layers for glucose detection redoubles upon blending GO with chitosan (GO+Ch) and increases up to eight times if covalent binding of chitosan to GO (GO-Ch) is exploited. In addition, the conductivity of the composite material GO-Ch is suitable for electrochemical applications without the need of GO reduction, which is generally required for GO based coatings. Covalent modification of GO is achieved by a standard carboxylic activation/amidation approach by exploiting the abundant amino pendants of chitosan. Successful functionalization is proved by comparison with an ad-hoc synthesized control sample realized by using non-activated GO as precursor. The composite GO-Ch was deposited on standard screen-printed electrodes by a drop-casting approach. Comparison with a chitosan-GO blend and with pristine GO demonstrated the superior reliability and efficiency of the electrochemical response for glucose as a consequence of the high number of enzyme binding sites and of the partial reduction of GO during the carboxylic activation synthetic step.
2020
Istituto per la Microelettronica e Microsistemi - IMM
Istituto per la Sintesi Organica e la Fotoreattivita' - ISOF
graphene oxide
nanocomposites
glucose sensing
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/381918
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 20
social impact