Since theoretical models provide data that cannot be otherwise gathered, numerical methods applied to medical devices analysis have emerged as fundamental tool in preclinical development. Large efforts were done to study mechanical and drug-eluting properties in stents but often the coating modelling is neglected. This work presents a finite element framework to calculate mechanical loads and drug distribution in three commercial drug-eluting stents (Palmaz-Schatz, Palmaz Genesis and Multi Link Vision), to check coatings strength and drug distribution maps in biological tissues. The promising copolymer poly(methylmethacrylate-co-n-butylmethacrylate), loaded with paclitaxel, is analyzed. Results demonstrated that the coating undergoes localized plastic phenomena, and calculated stresses are lower than the ultimate stress, ensuring coating integrity. Computed drug concentration depends on stent geometry and its values are in all cases lower than the toxicity level for this drug.

Numerical analysis of paclitaxel-eluting coronary stents: Mechanics and drug release properties

Gagliardi M
2020

Abstract

Since theoretical models provide data that cannot be otherwise gathered, numerical methods applied to medical devices analysis have emerged as fundamental tool in preclinical development. Large efforts were done to study mechanical and drug-eluting properties in stents but often the coating modelling is neglected. This work presents a finite element framework to calculate mechanical loads and drug distribution in three commercial drug-eluting stents (Palmaz-Schatz, Palmaz Genesis and Multi Link Vision), to check coatings strength and drug distribution maps in biological tissues. The promising copolymer poly(methylmethacrylate-co-n-butylmethacrylate), loaded with paclitaxel, is analyzed. Results demonstrated that the coating undergoes localized plastic phenomena, and calculated stresses are lower than the ultimate stress, ensuring coating integrity. Computed drug concentration depends on stent geometry and its values are in all cases lower than the toxicity level for this drug.
2020
Istituto Nanoscienze - NANO
Drug-eluting stentFinite element modelMechanical stressDrug delivery
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/382908
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? ND
social impact