In this work, the development and testing of a novel fiber-optic based label-free biosensor is presented, whose performance were verified through the detection of C-reactive protein (CRP) in serum. The device is based on a long period grating fabricated in a double cladding fiber with a W-shaped refractive index (RI) profile. As a result, the working point of the device was tuned to the mode transition region by chemical etching of the outer fiber cladding, obtaining a significant enhancement of the RI sensitivity and an excellent visibility of the grating resonances due to the mode transition in an all-silica structure. The fiber transducer was coated with a nanometric thin layer of graphene oxide in order to provide functional groups for the covalent immobilization of the biological recognition element. A very low limit of detection of about 0.15?ng/mL was obtained during the detection of CRP in serum, and a large working range (1?ng/mL - 100??g/mL) of clinical relevance has been also achieved.
Long period grating in double cladding fiber coated with graphene oxide as high-performance optical platform for biosensing
Lucia Sansone;Francesco Baldini;Francesco Chiavaioli
;Michele Giordano
;Ambra Giannetti;
2021
Abstract
In this work, the development and testing of a novel fiber-optic based label-free biosensor is presented, whose performance were verified through the detection of C-reactive protein (CRP) in serum. The device is based on a long period grating fabricated in a double cladding fiber with a W-shaped refractive index (RI) profile. As a result, the working point of the device was tuned to the mode transition region by chemical etching of the outer fiber cladding, obtaining a significant enhancement of the RI sensitivity and an excellent visibility of the grating resonances due to the mode transition in an all-silica structure. The fiber transducer was coated with a nanometric thin layer of graphene oxide in order to provide functional groups for the covalent immobilization of the biological recognition element. A very low limit of detection of about 0.15?ng/mL was obtained during the detection of CRP in serum, and a large working range (1?ng/mL - 100??g/mL) of clinical relevance has been also achieved.File | Dimensione | Formato | |
---|---|---|---|
prod_435255-doc_170048.pdf
solo utenti autorizzati
Descrizione: Long period grating in double cladding fiber coated with graphene oxide as high-performance optical platform for biosensing
Tipologia:
Versione Editoriale (PDF)
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
5.75 MB
Formato
Adobe PDF
|
5.75 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.