Routine studies are performed on JET using a new set of antennas to excite Toroidal Alfvén Eigenmodes (TAE). A TAE resonance footprint is observed in the plasma response measurement when there is a noticeable variation in both the amplitude and the phase of the response with respect to the excitation. An algorithm for real-time identification of TAE resonances, based on a hardware lock-in amplifier, is presently used at the Joint European Torus (JET) tokamak for detecting such variations. In this paper, we revisit the problem of estimating the I-Q characteristics from a known non-stationary frequency mode, with a resonant-like phase response, embedded in a digital signal. A non-stationary linear model is used in a recursive filter implementation of a lock-in amplifier. We propose it as a viable alternative to hardware synchronous detectors such as the one in use at the JET and compare its' performance with standard digital lock-in techniques in terms of bandwidth and phase response under high throughput rates requirements.

A Real-Time Synchronous Detector for the TAE Antenna Diagnostic at JET

Murari A;
2010

Abstract

Routine studies are performed on JET using a new set of antennas to excite Toroidal Alfvén Eigenmodes (TAE). A TAE resonance footprint is observed in the plasma response measurement when there is a noticeable variation in both the amplitude and the phase of the response with respect to the excitation. An algorithm for real-time identification of TAE resonances, based on a hardware lock-in amplifier, is presently used at the Joint European Torus (JET) tokamak for detecting such variations. In this paper, we revisit the problem of estimating the I-Q characteristics from a known non-stationary frequency mode, with a resonant-like phase response, embedded in a digital signal. A non-stationary linear model is used in a recursive filter implementation of a lock-in amplifier. We propose it as a viable alternative to hardware synchronous detectors such as the one in use at the JET and compare its' performance with standard digital lock-in techniques in terms of bandwidth and phase response under high throughput rates requirements.
2010
Istituto gas ionizzati - IGI - Sede Padova
Diagnostics
Estimation
Plasma measurements
Real time systems
Signal processing
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/38476
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? ND
social impact