Methods Fifty-eight patients with clinical allergy to betalactam antibiotics and presenting positive skin tests to at least one of the allergens (minor determinant mixture (MDM), benzylpenicilloyl-polylysine (PPL), penicillin, ampicillin, amoxicillin, cephalosporins) were tested. Thirty subjects non-allergic to betalactams were also studied as controls. The flow assay stimulation test (FAST) uses flow cytometry to determine the percentage of basophils that express CD63 as an activation marker after in vitro stimulation with allergen. Double labelling with monoclonal antibodies anti-CD63-PE and anti-IgE FITC was used.

Background In this study, we used flow cytometry to determine the percentage of activated basophils that expressed the CD63 marker after in vitro stimulation by different betalactam antibiotics. The diagnostic reliability of the technique was assessed, as well as its correlation with specific IgE.

Flow cytometric basophil activation test by detection of CD63 expression in patients with immediate-type reactions to betalactam antibiotics

Uasuf C;
2002

Abstract

Background In this study, we used flow cytometry to determine the percentage of activated basophils that expressed the CD63 marker after in vitro stimulation by different betalactam antibiotics. The diagnostic reliability of the technique was assessed, as well as its correlation with specific IgE.
2002
Methods Fifty-eight patients with clinical allergy to betalactam antibiotics and presenting positive skin tests to at least one of the allergens (minor determinant mixture (MDM), benzylpenicilloyl-polylysine (PPL), penicillin, ampicillin, amoxicillin, cephalosporins) were tested. Thirty subjects non-allergic to betalactams were also studied as controls. The flow assay stimulation test (FAST) uses flow cytometry to determine the percentage of basophils that express CD63 as an activation marker after in vitro stimulation with allergen. Double labelling with monoclonal antibodies anti-CD63-PE and anti-IgE FITC was used.
betalactam allergy
CD63 expression
flow cytometric basophil activation test
in vitro diagnosis
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/385618
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 277
  • ???jsp.display-item.citation.isi??? 235
social impact