ATHENA Silicon Pore Optics (SPO) Mirror Modules (MM) have to be tested and accepted prior to integration in the full ATHENA Mirror Assembly (MA). X-ray tests of the MMs are currently performed at the PTB laboratory of the BESSY synchrotron facility in pencil beam configuration, but they require a PSF reconstruction. Full illumination X-ray tests could be performed using a broad, low-divergent X-ray beam like the one in use at ANTER (MPE, Neuried, Germany), but the large volume to be evacuated makes it impossible to perform the functional tests at the MMs production rate (3 MM/day). To overcome these limitations, we started in 2012 to design a facility aimed at generating a broad (170 x 60 mm2), uniform and low-divergent (1.5 arcsec HEW) X-ray beam within a small lab (~ 9 x 18 m2), to characterize the ATHENA MM. BEaTriX (the Beam Expander Testing X-ray facility) makes use of an X-ray microfocus source, a paraboloidal mirror, a crystal monochromation system, and an asymmetrically-cut diffracting crystal for the beam expansion. These optical components, in addition to a modular low-vacuum level (10-3 mbar), enable to match the ATHENA SPO acceptance requirements. The realization of this facility at INAF-OAB in Merate (Italy) is now on going. Once completed, BEaTriX can be used to test the Silicon Pore Optics modules of the ATHENA X-ray observatory, as well as other optics, like the ones of the Arcus mission. In this paper we report the advancement status of the facility.

BEaTriX (Beam Expander Testing X-ray facility) for testing ATHENA's SPO modules: advancement status

C Ferrari;A Zappettini;
2018

Abstract

ATHENA Silicon Pore Optics (SPO) Mirror Modules (MM) have to be tested and accepted prior to integration in the full ATHENA Mirror Assembly (MA). X-ray tests of the MMs are currently performed at the PTB laboratory of the BESSY synchrotron facility in pencil beam configuration, but they require a PSF reconstruction. Full illumination X-ray tests could be performed using a broad, low-divergent X-ray beam like the one in use at ANTER (MPE, Neuried, Germany), but the large volume to be evacuated makes it impossible to perform the functional tests at the MMs production rate (3 MM/day). To overcome these limitations, we started in 2012 to design a facility aimed at generating a broad (170 x 60 mm2), uniform and low-divergent (1.5 arcsec HEW) X-ray beam within a small lab (~ 9 x 18 m2), to characterize the ATHENA MM. BEaTriX (the Beam Expander Testing X-ray facility) makes use of an X-ray microfocus source, a paraboloidal mirror, a crystal monochromation system, and an asymmetrically-cut diffracting crystal for the beam expansion. These optical components, in addition to a modular low-vacuum level (10-3 mbar), enable to match the ATHENA SPO acceptance requirements. The realization of this facility at INAF-OAB in Merate (Italy) is now on going. Once completed, BEaTriX can be used to test the Silicon Pore Optics modules of the ATHENA X-ray observatory, as well as other optics, like the ones of the Arcus mission. In this paper we report the advancement status of the facility.
2018
Istituto dei Materiali per l'Elettronica ed il Magnetismo - IMEM
BEaTriX
X-ray test facility
micro-focus source
beam expander
asymmetric diffraction
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/388020
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? ND
social impact