ATHENA Silicon Pore Optics (SPO) Mirror Modules (MM) have to be tested and accepted prior to integration in the full ATHENA Mirror Assembly (MA). X-ray tests of the MMs are currently performed at the PTB laboratory of the BESSY synchrotron facility in pencil beam configuration, but they require a PSF reconstruction. Full illumination X-ray tests could be performed using a broad, low-divergent X-ray beam like the one in use at ANTER (MPE, Neuried, Germany), but the large volume to be evacuated makes it impossible to perform the functional tests at the MMs production rate (3 MM/day). To overcome these limitations, we started in 2012 to design a facility aimed at generating a broad (170 x 60 mm2), uniform and low-divergent (1.5 arcsec HEW) X-ray beam within a small lab (~ 9 x 18 m2), to characterize the ATHENA MM. BEaTriX (the Beam Expander Testing X-ray facility) makes use of an X-ray microfocus source, a paraboloidal mirror, a crystal monochromation system, and an asymmetrically-cut diffracting crystal for the beam expansion. These optical components, in addition to a modular low-vacuum level (10-3 mbar), enable to match the ATHENA SPO acceptance requirements. The realization of this facility at INAF-OAB in Merate (Italy) is now on going. Once completed, BEaTriX can be used to test the Silicon Pore Optics modules of the ATHENA X-ray observatory, as well as other optics, like the ones of the Arcus mission. In this paper we report the advancement status of the facility.

BEaTriX (Beam Expander Testing X-ray facility) for testing ATHENA's SPO modules: advancement status

C Ferrari;A Zappettini;
2018

Abstract

ATHENA Silicon Pore Optics (SPO) Mirror Modules (MM) have to be tested and accepted prior to integration in the full ATHENA Mirror Assembly (MA). X-ray tests of the MMs are currently performed at the PTB laboratory of the BESSY synchrotron facility in pencil beam configuration, but they require a PSF reconstruction. Full illumination X-ray tests could be performed using a broad, low-divergent X-ray beam like the one in use at ANTER (MPE, Neuried, Germany), but the large volume to be evacuated makes it impossible to perform the functional tests at the MMs production rate (3 MM/day). To overcome these limitations, we started in 2012 to design a facility aimed at generating a broad (170 x 60 mm2), uniform and low-divergent (1.5 arcsec HEW) X-ray beam within a small lab (~ 9 x 18 m2), to characterize the ATHENA MM. BEaTriX (the Beam Expander Testing X-ray facility) makes use of an X-ray microfocus source, a paraboloidal mirror, a crystal monochromation system, and an asymmetrically-cut diffracting crystal for the beam expansion. These optical components, in addition to a modular low-vacuum level (10-3 mbar), enable to match the ATHENA SPO acceptance requirements. The realization of this facility at INAF-OAB in Merate (Italy) is now on going. Once completed, BEaTriX can be used to test the Silicon Pore Optics modules of the ATHENA X-ray observatory, as well as other optics, like the ones of the Arcus mission. In this paper we report the advancement status of the facility.
2018
Istituto dei Materiali per l'Elettronica ed il Magnetismo - IMEM
Inglese
Sodnick, Z; Karafolas, N; Cugny, B
INTERNATIONAL CONFERENCE ON SPACE OPTICS-ICSO 2018
International Conference on Space Optics--ICSO 2018
1118026-1
10
https://www.spiedigitallibrary.org/conference-proceedings-of-spie/11180/2535997/BEaTriX-Beam-Expander-Testing-X-ray-facility-for-testing-ATHENAs/10.1117/12.2535997.full
SPIE-INT SOC OPTICAL ENGINEERING
BELLINGHAM, WA 98227-0010
STATI UNITI D'AMERICA
Sì, ma tipo non specificato
09-12/10/2018
Chania, Greece
BEaTriX
X-ray test facility
micro-focus source
beam expander
asymmetric diffraction
20
none
Salmaso, B; Basso, S; Ghigo, M; Giro, E; Pareschi, G; Spiga, D; G Tagliaferri, B; Gvecchi, ; Pelliciari, C; Burwitz, V; Sanchez del Rio, M; Ferrari, C...espandi
273
info:eu-repo/semantics/conferenceObject
04 Contributo in convegno::04.01 Contributo in Atti di convegno
   Integrated Activities for the High Energy Astrophysics Domain
   AHEAD
   H2020
   654215
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/388020
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 3
social impact