Gated integrating measurement method represents a widely used approach when fast, repetitive analogue signals are concerned. In this work a compact synchronized gated-integrator prototype has been realized and preliminary characterized. Front-end electronics is based on the mature high-precision switched-integrator transimpedance-amplifier IVC102 whose output is connected to a precision LT1911 inverting amplifier, whereas analogue-to-digital conversion, as well as timing control circuitry, are performed by a high-efficiency LPC845 microcontroller. Synchronizing signal detection with the external trigger generated in coincidence with a source, the proposed circuitry amplifies and integrates the signal only when the pulse is generated, displaying excellent performances in terms of linearity, sensitivity and signal-to-noise ratio. Hence, the proposed solution represents an affordable alternative to continuous-time regime measurement-techniques, usually adopted in radiation dosimetry where accuracy and sensitivity are strict requirements for treatment quality assurance

A High-Precision Gated Integrator for Repetitive Pulsed Signals Acquisition

S. Pettinato;A. Orsini;M. Girolami;D. M. Trucchi;S. Salvatori
2019

Abstract

Gated integrating measurement method represents a widely used approach when fast, repetitive analogue signals are concerned. In this work a compact synchronized gated-integrator prototype has been realized and preliminary characterized. Front-end electronics is based on the mature high-precision switched-integrator transimpedance-amplifier IVC102 whose output is connected to a precision LT1911 inverting amplifier, whereas analogue-to-digital conversion, as well as timing control circuitry, are performed by a high-efficiency LPC845 microcontroller. Synchronizing signal detection with the external trigger generated in coincidence with a source, the proposed circuitry amplifies and integrates the signal only when the pulse is generated, displaying excellent performances in terms of linearity, sensitivity and signal-to-noise ratio. Hence, the proposed solution represents an affordable alternative to continuous-time regime measurement-techniques, usually adopted in radiation dosimetry where accuracy and sensitivity are strict requirements for treatment quality assurance
2019
Istituto di Struttura della Materia - ISM - Sede Secondaria Montelibretti
Inglese
8
1231
14
https://www.mdpi.com/2079-9292/8/11/1231
Sì, ma tipo non specificato
Gated integrator
Pulsed signal
Synchronized integration
State configurable timer
Radiation dosimetry
Front-end electronics
Read-out electronics
Analog electronics
Internazionale
Elettronico
No
6
info:eu-repo/semantics/article
262
Pettinato, S.; Orsini, A.; Girolami, M.; Trucchi, D. M.; Rossi, M. C.; Salvatori, S.
01 Contributo su Rivista::01.01 Articolo in rivista
open
File in questo prodotto:
File Dimensione Formato  
prod_408487-doc_143372.pdf

accesso aperto

Descrizione: published online
Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 4.44 MB
Formato Adobe PDF
4.44 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/388707
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 18
social impact