Optical Emission Spectroscopy (OES) on SPIDER Negative Ion Source [1] has been collecting data since beginning of operation in summer 2018. First months were devoted to complete the diagnostic commissioning and its integration with SPIDER Control and Data Acquisition System (CODAS) [2]. Consistent sets of spectroscopic data have been acquired under different experimental conditions, varying not only the plasma source filling pressure and injected power, but also changing the RF generators frequencies and the strength of the magnetic field acting as filter in front of the plasma grid. The main results of OES data analysis are presented in this work. Spider optical emission diagnostic comprises a set of 66 channels wavelength resolved, and 36 single line channels by means of interference filtered. Some of them collect the photons along line of sights (LOS) perpendicular to the grids through the 8 RF drivers, others along LOS parallel to and near the grids, both horizontally and vertically. Since the starting of extraction experiments, 22 channels have been dedicated to collect the extracted beam emission. The LOS layout allows tracing two 9-points vertical profiles of the source plasma in the expansion region at 35 and 5 millimeters from the Plasma Grid (PG), and four 4-points horizontal profiles spanning the 65 mm region before the PG. It is also possible to collect spectra from LOS looking in between the grids. Both Balmer series and Fulcher band between 600 nm and 640 nm were routinely collected. Their intensities are very sensitive to the plasma parameters, and when coupled to a collisional radiative model can give precious insights to electron density and gas dissociation. It has been found that Balmer emission and gas dissociation inside the drivers scale linearly with the RF power, the latter reaching value up to 20% at high power and low pressure. Rotational gas temperature has been also measured; it ranged between 900 K and 1400 K, where higher values were reached for higher pressures and RF powers.

First measurements of Optical Emission Spectroscopy on SPIDER Negative Ion Source

Barbisan M;Bruno D;Pasqualotto R;Taliercio C;
2019

Abstract

Optical Emission Spectroscopy (OES) on SPIDER Negative Ion Source [1] has been collecting data since beginning of operation in summer 2018. First months were devoted to complete the diagnostic commissioning and its integration with SPIDER Control and Data Acquisition System (CODAS) [2]. Consistent sets of spectroscopic data have been acquired under different experimental conditions, varying not only the plasma source filling pressure and injected power, but also changing the RF generators frequencies and the strength of the magnetic field acting as filter in front of the plasma grid. The main results of OES data analysis are presented in this work. Spider optical emission diagnostic comprises a set of 66 channels wavelength resolved, and 36 single line channels by means of interference filtered. Some of them collect the photons along line of sights (LOS) perpendicular to the grids through the 8 RF drivers, others along LOS parallel to and near the grids, both horizontally and vertically. Since the starting of extraction experiments, 22 channels have been dedicated to collect the extracted beam emission. The LOS layout allows tracing two 9-points vertical profiles of the source plasma in the expansion region at 35 and 5 millimeters from the Plasma Grid (PG), and four 4-points horizontal profiles spanning the 65 mm region before the PG. It is also possible to collect spectra from LOS looking in between the grids. Both Balmer series and Fulcher band between 600 nm and 640 nm were routinely collected. Their intensities are very sensitive to the plasma parameters, and when coupled to a collisional radiative model can give precious insights to electron density and gas dissociation. It has been found that Balmer emission and gas dissociation inside the drivers scale linearly with the RF power, the latter reaching value up to 20% at high power and low pressure. Rotational gas temperature has been also measured; it ranged between 900 K and 1400 K, where higher values were reached for higher pressures and RF powers.
2019
Istituto per la Scienza e Tecnologia dei Plasmi - ISTP
Optical Emission Spectroscopy
OES
SPIDER Negative Ion Source
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/390207
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact