The determination of the volume of eye muscles is a problem of considerable interest in Graves' ophthalmopathy both with respect to the diagnostic quantisation of the disease and to the measured assessment of the effectiveness of pharmacological treatment. The aim of this research is to design and test an advanced method for processing computerised tomography (CT) orbital images in order to obtain a three-dimensional reconstruction of infra-orbital muscle structures and to analyse them from a morphometric viewpoint. CT images of subjects suffering from Graves' disease were acquired before and after pharmacological treatment with immunosuppressors. They were then processed along with CT images of an anatomical phantom of known volume and fusiform morphology in order to assess the reliability of the procedure and to calculate the effect of the different modalities of acquisition and processing of CT images on the error in volume calculation.

Volumetric analysis of CT orbital images

Salvetti O
1998

Abstract

The determination of the volume of eye muscles is a problem of considerable interest in Graves' ophthalmopathy both with respect to the diagnostic quantisation of the disease and to the measured assessment of the effectiveness of pharmacological treatment. The aim of this research is to design and test an advanced method for processing computerised tomography (CT) orbital images in order to obtain a three-dimensional reconstruction of infra-orbital muscle structures and to analyse them from a morphometric viewpoint. CT images of subjects suffering from Graves' disease were acquired before and after pharmacological treatment with immunosuppressors. They were then processed along with CT images of an anatomical phantom of known volume and fusiform morphology in order to assess the reliability of the procedure and to calculate the effect of the different modalities of acquisition and processing of CT images on the error in volume calculation.
1998
Istituto di Scienza e Tecnologie dell'Informazione "Alessandro Faedo" - ISTI
CT images
Error estimate
Eye muscles
Image sequence processing
Volumetric analysis
File in questo prodotto:
File Dimensione Formato  
prod_410554-doc_144493.pdf

solo utenti autorizzati

Descrizione: Volumetric analysis of CT orbital images
Tipologia: Versione Editoriale (PDF)
Dimensione 696.37 kB
Formato Adobe PDF
696.37 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/391398
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 12
social impact